2016
DOI: 10.1016/j.measurement.2016.05.055
|View full text |Cite
|
Sign up to set email alerts
|

Design and implementation of an error detection and correction method compatible with MODBUS-RTU by means of systematic codes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“…is alternative is economical and especially suitable for the implementation of energy management systems in facilities with segments prone to transmission errors caused by electromagnetic interference, for example, old buildings. e proposed solution extends the scope of a previous study that dealt with error detection and correction systems for the Modbus-RTU protocol by means of systematic codes [24].…”
Section: Justification and Related Studiesmentioning
confidence: 70%
See 2 more Smart Citations
“…is alternative is economical and especially suitable for the implementation of energy management systems in facilities with segments prone to transmission errors caused by electromagnetic interference, for example, old buildings. e proposed solution extends the scope of a previous study that dealt with error detection and correction systems for the Modbus-RTU protocol by means of systematic codes [24].…”
Section: Justification and Related Studiesmentioning
confidence: 70%
“…e method proposed in [24] allows the improvement of transmission quality in Modbus-RTU communications in environments with high electromagnetic interference. is is performed using retransmitters able to detect and correct errors on the receptor side by employing systemic codes like Reed-Solomon's, as shown in Figure 2.…”
Section: Basis Of This Proposalmentioning
confidence: 99%
See 1 more Smart Citation
“…In [17], the authors have addressed the transmission quality improvement in industrial communications based on Modbus RTU, using relay devices with the ability to detect and correct errors. This method respects the Modbus RTU protocol parameters, so that the enhanced bus with relay devices can be used together with common devices.…”
Section: Related Workmentioning
confidence: 99%
“…Tests performed on repeaters/error correctors validate the fulfillment of design requirements and demonstrate their effectiveness in improving transmission quality for industrial Modbus RTU data transmission networks. The authors in [17] present the design and implementation of error detection and correction scheme in a Modbus RTU network based on the REED-SOLOMON code. Parity bits transmission is done following Modbus protocol parameters, so the bus can be used by common devices without error detection/correction scheme.…”
Section: Related Workmentioning
confidence: 99%