2019
DOI: 10.1155/2019/7010717
|View full text |Cite
|
Sign up to set email alerts
|

Enhancing Modbus-RTU Communications for Smart Metering in Building Energy Management Systems

Abstract: In this work, a method for detecting and correcting errors in Modbus-RTU communications is designed, implemented, and assessed in a smart metering application. This is a low-cost solution for improving communication quality in conventional Modbus-RTU architectures with copper fieldbus. It consists of introducing error detection and correction devices in the network segments most susceptible to errors caused by electromagnetic interference. Experimental validations were conducted and demonstrated the effectiven… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 22 publications
(27 reference statements)
0
3
0
Order By: Relevance
“…Fig. 5 shows the structure of the data frame in Modbus RTU, including four message structures: address, function code, data and CRC (cyclic redundancy check) [26]. The first three fields contain the necessary information for Modbus transactions, while the fourth field corresponds to a 16-bit CRC calculation to detect errors.…”
Section: ) Modbus Protocolmentioning
confidence: 99%
“…Fig. 5 shows the structure of the data frame in Modbus RTU, including four message structures: address, function code, data and CRC (cyclic redundancy check) [26]. The first three fields contain the necessary information for Modbus transactions, while the fourth field corresponds to a 16-bit CRC calculation to detect errors.…”
Section: ) Modbus Protocolmentioning
confidence: 99%
“…The results obtained from simulations and experimental tests validated the effectiveness of the proposed method to increase the data rate while maintaining the reliability of the protocol. Researchers performed experimental validations demonstrating the effectiveness of the proposed method in isolating the segments susceptible to disturbances in a communication bus [17]. This maintained the compatibility with commercial devices and improved the performance of the entire network.…”
Section: Related Workmentioning
confidence: 91%
“…To optimize the SoC of BSS in the EVCS during the off-peak duration, the optimization approach is employed for the estimation of solar generation and EVs charging load is referred to in Figure 2. Figure 2 highlights the features of a coordinated system through supervisory control for bidirectional communication with VSI over MODBUS and the EMS for storage over CANBUS [45]. The intelligent coordinated controller uses the past data from the PV panels to estimate the available DG power and estimates the required EVs charging loads based on previous charging patterns and weather conditions.…”
Section: Coordinated Control Strategymentioning
confidence: 99%