2020
DOI: 10.1007/s00202-020-01067-7
|View full text |Cite
|
Sign up to set email alerts
|

Error detection and correction to enhance the data rate of smart metering systems using Modbus-RTU

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…Security analysis involves protocol verification considering different types of attacks and basic cybersecurity services, such as integrity and confidentiality [15]. Current research has focused on how Modbus-RTU can be improved considering various aspects of communication performance [16]. The results obtained from simulations and experimental tests validated the effectiveness of the proposed method to increase the data rate while maintaining the reliability of the protocol.…”
Section: Related Workmentioning
confidence: 89%
“…Security analysis involves protocol verification considering different types of attacks and basic cybersecurity services, such as integrity and confidentiality [15]. Current research has focused on how Modbus-RTU can be improved considering various aspects of communication performance [16]. The results obtained from simulations and experimental tests validated the effectiveness of the proposed method to increase the data rate while maintaining the reliability of the protocol.…”
Section: Related Workmentioning
confidence: 89%
“…MPC techniques will be used to solve different control issues in SG. MPC have ability to predict future results according to previous experience; we use MPC here at user end (Sotelo et al, 2022;Elmorshedy et al, 2021) with IAM to keep recording previous error solutions, energy consumption data records (Urrea et al, 2021), billing records, and predict future action automatically according to experience as well as predict future energy consumption in advance which will help to inform the service provider about capacity of power production their future consumption capacity as shown in Figure .5. MPC have few more benefits mentioned below.…”
Section: Iam Architecturementioning
confidence: 99%
“…Another research and development direction for Modbus RTU refers to methods of detection and correction of errors. In [ 17 ], error detection was performed using a specialized repeater device in the receiver and transmitter. This method complies with the parameters of the Modbus RTU protocol; thus, the bus extension with the retransmission devices can also be achieved with normal Modbus RTU devices.…”
Section: Related Workmentioning
confidence: 99%