2015
DOI: 10.1016/j.ceramint.2015.03.256
|View full text |Cite
|
Sign up to set email alerts
|

Design and fabrication of high frequency BNT film based linear array transducer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 27 publications
(18 reference statements)
0
5
0
Order By: Relevance
“…We investigated the effects of other factors, i.e., oxygen vacancies, , ferroelectric polarization, and the piezopotential of bismuth sodium titanate (BNT), on H 2 production and methylene blue (MB, 20 mg L –1 ) degradation in this study. Ferroelectric materials that do not contain lead have been extensively studied and used in ultrasonic transducers and resonators. , Because of the A-site cation substitution in the perovskite structure, BNT has the unusual property of maintaining its energetically stable structure and composition. BNT differs from other relaxor ferroelectric materials in that it has cations with different valencies at its A sites, sodium and bismuth.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…We investigated the effects of other factors, i.e., oxygen vacancies, , ferroelectric polarization, and the piezopotential of bismuth sodium titanate (BNT), on H 2 production and methylene blue (MB, 20 mg L –1 ) degradation in this study. Ferroelectric materials that do not contain lead have been extensively studied and used in ultrasonic transducers and resonators. , Because of the A-site cation substitution in the perovskite structure, BNT has the unusual property of maintaining its energetically stable structure and composition. BNT differs from other relaxor ferroelectric materials in that it has cations with different valencies at its A sites, sodium and bismuth.…”
Section: Introductionmentioning
confidence: 99%
“…Ferroelectric materials that do not contain lead have been extensively studied and used in ultrasonic transducers and resonators. 33,34 Because of the A-site cation substitution in the perovskite structure, BNT has the unusual property of maintaining its energetically stable structure and composition. BNT differs from other relaxor ferroelectric materials in that it has cations with different valencies at its A sites, sodium and bismuth.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Then, the design of the UT can be conducted based on ECM. In this study, the design parameters of the UT are the thicknesses of the piezoelectric and matching layers, and the performance parameters include center frequency (CF) and bandwidth (BW), which can be calculated as [ 36 ] where and represent the lower and upper frequencies at which the amplitude drops to the −6 dB peak.…”
Section: Optimization Design Methods For Ultrasonic Transducermentioning
confidence: 99%
“…Fei et al fabricated Co-doped NBT (NBT-Co) piezoelectric ceramics to improve the piezoelectric properties of NBT ceramics and designed a 0.7 0.7 mm needle ultrasound transducer with a center frequency of 72.7 MHz (-6 dB bandwidth: 52.7%) and -number close to 1 [ 48 ]. Liu et al fabricated a 2 16 array 82.84 MHz (-6 dB bandwidth: 46.77%) millimeter transducer using an NBT-based thick film [ 71 ].…”
Section: Ultrasound Transducer Design and Fabricationmentioning
confidence: 99%