Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
47
0

Year Published

1998
1998
2010
2010

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 109 publications
(49 citation statements)
references
References 13 publications
1
47
0
Order By: Relevance
“…The used of dry film resists (DFR) were originally developed for printed circuit board (PCB) fabrication (Dempsey et al 1997). It is also available as etching resists and solder mask (Svasek et al 1996).…”
Section: Epoxy Laminatementioning
confidence: 99%
“…The used of dry film resists (DFR) were originally developed for printed circuit board (PCB) fabrication (Dempsey et al 1997). It is also available as etching resists and solder mask (Svasek et al 1996).…”
Section: Epoxy Laminatementioning
confidence: 99%
“…Nowadays, a wide array of bead particles (predominantly with a core of Sephadex type copolymers) with various surface characteristics are commercially available, and in the following section will be described procedures for real-time monitoring of cellular activities via immobilized live cells (15,72), isolation and on-column fluorimetric detection of DNA (15), optimization of immobilization protocols for proteins (74), as well as investigation of biomolecular association and dissociation processes as exploited in enzyme-linked immunosorbent assays (75) and affinity chromatographic methods (59,60,76). Yet before that, it might be of interest to compare the LOV with the socalled micro-total analysis systems (μTAS) (77), or as they lately have been termed Lab-on-a-Chips (LOC), which are exploited for bionanotechnological applications (78,79).…”
Section: X6 Microfluidic Devices: Lab-on-valvementioning
confidence: 99%
“…The biosensor chip with four individually addressable Pt electrodes with immobilized microbial strains was used in a flow system to measure oxygen consumption in the presence of assimilable microorganisms [126]. A miniaturized flow analytical system with an array of glucose and lactate biosensors was developed for on-line lactate and glucose monitoring in biological samples [127]. The complete system incorporates a microdialysis probe for intravascular monitoring and a silicon micromachined stack with an incorporated miniaturized flow cell/ sensor array.…”
Section: Miniaturization In Flow Electroanalysismentioning
confidence: 99%