1992
DOI: 10.1016/0198-0149(92)90080-d
|View full text |Cite
|
Sign up to set email alerts
|

Design and calibration of a new optical plankton counter capable of sizing small zooplankton

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
164
0
2

Year Published

2000
2000
2020
2020

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 185 publications
(169 citation statements)
references
References 5 publications
3
164
0
2
Order By: Relevance
“…That increase was dominated by copepods with approximate lengths of 1 mm. These copepods would be ideally sampled by the OPC in the size range 0.65 -1.35 mm ESD (Herman, 1992; following particle length approximately 1.5 times ESD according to Beaulieu et al, 1999) and it is likely that the OPC data reflect their increased abundance in the frontal jet. The lack of diel migratory signal in both the acoustic and OPC data for this patch also agreed with previous observations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…That increase was dominated by copepods with approximate lengths of 1 mm. These copepods would be ideally sampled by the OPC in the size range 0.65 -1.35 mm ESD (Herman, 1992; following particle length approximately 1.5 times ESD according to Beaulieu et al, 1999) and it is likely that the OPC data reflect their increased abundance in the frontal jet. The lack of diel migratory signal in both the acoustic and OPC data for this patch also agreed with previous observations.…”
Section: Discussionmentioning
confidence: 99%
“…The OPC estimates the Equivalent Spherical Diameter (ESD) of particles which break a 640 nm wavelength LED light beam. The instrument is designed to resolve ESD's between 250 µm and 3 mm (Herman, 1992), which represent approximate lengths of 500 µm to 30 mm (Huntley et al, 1995). Processing of the OPC data files followed the route developed by Pollard et al (1996).…”
Section: Opc Measurementsmentioning
confidence: 99%
“…As a particle passes the sensor, the portion of blocked light is measured and recorded as a digital size and converted to an ESD. This value represents the diameter of a sphere that would have the same cross-sectional area as the particle being measured, using a semiempirical formula based on calibration with black spheres of known diameters (Herman 1992;Herman et al 2004). Processing the raw LOPC data requires extensive post-processing filtering and interpretation in several steps.…”
Section: Methodsmentioning
confidence: 99%
“…Upon reaching the Seychelles, the samples from the ¢rst leg were sub-sampled and processed through an optical plankton counter (OPC; Herman, 1992) at the Shoals of Capricorn base. The mesozooplankton samples from the second leg were similarly sub-sampled and processed, using identical equipment, at the Shoals of Capricorn base on Rodrigues Island, Mauritius.…”
Section: Methodsmentioning