2019
DOI: 10.1016/j.mee.2019.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Deposition of hydrogen chloride gas on copper wafer depending on humidity and HCl concentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…The properties of the four copper surfaces were revealed by XPS and were compared with previous experimental findings reported elsewhere in the literature [ 21 , 22 , 23 , 24 , 25 , 26 , 28 , 29 ]. The unheated (UH) copper surface consisted of both Cu (Cu 0 ) and Cu 2 O (Cu + ) ( Figure 4 and Table 4 ), gradually changing from Cu to Cu 2 O over time [ 4 , 24 , 26 ].…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…The properties of the four copper surfaces were revealed by XPS and were compared with previous experimental findings reported elsewhere in the literature [ 21 , 22 , 23 , 24 , 25 , 26 , 28 , 29 ]. The unheated (UH) copper surface consisted of both Cu (Cu 0 ) and Cu 2 O (Cu + ) ( Figure 4 and Table 4 ), gradually changing from Cu to Cu 2 O over time [ 4 , 24 , 26 ].…”
Section: Discussionmentioning
confidence: 94%
“…This absence of the satellite peaks suggested that the formed copper-oxide layer (oxide film) had been removed by HCl, as previously reported for a copper-containing gold–silver–palladium alloy [ 10 ]. The narrow-scan spectra ( Figure 4 and Table 4 ) suggested that CuCl 2 (Cu 2+ and Cl − ) and the gas-phase water (H 2 O) occurred by a chemical reaction between CuO and HCl [ 25 , 26 , 29 ]. The spectra in the Cu LMM region indicated that the AC specimen surface was not covered by CuO, and the surface consisted of CuO 2 , CuCl 2 , and Cu ( Figure 4 b and Table 4 ).…”
Section: Discussionmentioning
confidence: 99%
“…The source of these acidic contaminants may originate from processes bearing fluorine or chlorine chemistry. A recent study reported by Tran et al 18 clarifies the role of humidity and HCl concentration in the air played in the corrosion of copper-coated wafer surfaces. By controlling the exposure conditions with the relative humidity varying between <1% and 70% and HCl concentration between 20 ppbv and 450 ppbv, the investigators were able to establish an empirical correlation of surface chlorine deposition as a function of exposure time and concentration, independent of RH within the tested range:…”
Section: Current Knowledge About Amcsmentioning
confidence: 88%
“…The release has little effect at low temperature, but it aggravates the release of HCl during combustion at medium-high temperature. At the same time, mixed burning of municipal solid waste will show a higher HCl release [16][17][18][19][20]. Municipal solid waste incineration will release a large number of HCl pollutant gas, not only will corrode the metal pipe wall, shorten the service life of the equipment, at the same time, in the presence of carbon sources will produce dioxin precursors, which seriously harm to life and ecological environment [21,22].…”
Section: Introductionmentioning
confidence: 99%