2016
DOI: 10.1016/j.fluid.2016.04.024
|View full text |Cite
|
Sign up to set email alerts
|

Densities and derived thermophysical properties of the 0.9505 CO2+ 0.0495 H2S mixture from 273 K to 353 K and pressures up to 41 MPa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 30 publications
(29 citation statements)
references
References 37 publications
1
28
0
Order By: Relevance
“…Different CO 2 capture processes produce different levels of impurities (Table ). Typically, the concentration of CO 2 will be between 90% and 99%, which may seem very pure; however, phase behavior and physical properties of highly CO 2 rich fluids are affected by impurities . Fig.…”
Section: Challenges Of Metering Technologies For Ccsmentioning
confidence: 99%
See 2 more Smart Citations
“…Different CO 2 capture processes produce different levels of impurities (Table ). Typically, the concentration of CO 2 will be between 90% and 99%, which may seem very pure; however, phase behavior and physical properties of highly CO 2 rich fluids are affected by impurities . Fig.…”
Section: Challenges Of Metering Technologies For Ccsmentioning
confidence: 99%
“…Unreliable density predictions will therefore lead to measurement error. Uncertainties around the EoS for mixtures of CO 2 with impurities have been discussed for classical cubic equations of states, for example Peng‐Robison (PR‐EoS) and Soave‐Redlich‐Kwong (SRK‐EoS), as well as multi‐parameter EoS, GERG ,, . In general, the accuracy of these equations in the vicinity of two‐phase region would be expected to be weak.…”
Section: Challenges Of Metering Technologies For Ccsmentioning
confidence: 99%
See 1 more Smart Citation
“…A full description of the experimental set-up and procedures are available in Bouchot and Richon [14], Coquelet et al [15] and Nazeri et al [16]. The density of the studied mixture have been measured in a Hastelloy Vibrating Tube Densitometer (VTD), Anton Paar model DMA 512, using the one fluid reference calibration method [17].…”
Section: Equipment Descriptionmentioning
confidence: 99%
“…In this work, the PR, SAFT-VR Mie and GERG-2008 [13] EoSs were employed to predict the densities of mixtures and were implemented into the thermodynamic package HWPVT [16] [26] [27] [28] [29].…”
Section: Gergmentioning
confidence: 99%