2020
DOI: 10.1177/0309364620963943
|View full text |Cite
|
Sign up to set email alerts
|

Defining the design requirements for an assistive powered hand exoskeleton: A pilot explorative interview study and case series

Abstract: Background: Powered hand exoskeletons are an emerging technology that have shown promise in assisting individuals with impaired hand function. A number of hand exoskeleton designs have been described in the literature; however, the majority have not been supported by patient-oriented criteria. Objective: The aim of this study was to define preliminary end-user needs and expectations for an assistive hand exoskeleton. Study design: Explorative interview and case series. Methods: Six clinicians and eight individ… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(22 citation statements)
references
References 16 publications
0
16
0
2
Order By: Relevance
“…Here, an RPR architecture was preferred because it provides for a slider with a stroke independent of the first phalanx's length and can thus accommodate various anthropometries. In terms of encumbrance, the wearable parts of the platform, including the kinematic chain and the proximal cuff on the phalanx, are included in a volume of 28.66 cm 3 (88.26x26.75x12.14 mm), resulting in a compact design similar to the literature [29], [30] and in line with the acceptable encumbrance of 75 cm 3 (50x50x30 mm) for the whole hand proposed in [31].…”
Section: Discussionmentioning
confidence: 99%
“…Here, an RPR architecture was preferred because it provides for a slider with a stroke independent of the first phalanx's length and can thus accommodate various anthropometries. In terms of encumbrance, the wearable parts of the platform, including the kinematic chain and the proximal cuff on the phalanx, are included in a volume of 28.66 cm 3 (88.26x26.75x12.14 mm), resulting in a compact design similar to the literature [29], [30] and in line with the acceptable encumbrance of 75 cm 3 (50x50x30 mm) for the whole hand proposed in [31].…”
Section: Discussionmentioning
confidence: 99%
“…The precision grip requires only one degree of freedom (DOF), whereas the power grip requires two DOFs [21]. In both grips, the thumb should be opposed to the fingers [22]. Also, it is acceptable to couple the movements of the index and middle finger [22].…”
Section: Requirementsmentioning
confidence: 99%
“…In both grips, the thumb should be opposed to the fingers [22]. Also, it is acceptable to couple the movements of the index and middle finger [22]. The device should allow for some passive finger abduction/adduction of the MCP joint to accommodate slightly deformed hands and be comfortable during use.…”
Section: Requirementsmentioning
confidence: 99%
“…Wawancara dilakukan secara Synchronous menggunakan Google Meet dan direkam dalam bentuk audio / video. Rekaman audio / video digunakan untuk meninjau keakuratan dari hasil wawancara tersebut (Boser et al, 2020). Selain itu, rekaman juga digunakan untuk mengamati tanggapan yang diberikan secara berulang (Boser et al, 2020).…”
Section: B Interviewunclassified