2009 World Non-Grid-Connected Wind Power and Energy Conference 2009
DOI: 10.1109/wnwec.2009.5335795
|View full text |Cite
|
Sign up to set email alerts
|

Decoupling control of the non-grid-connected wind power system with the droop strategy based on a DC micro-grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
18
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(19 citation statements)
references
References 1 publication
0
18
0
Order By: Relevance
“…Thus, they suffer from low reliability and high cost. Another solution is the application of the voltage of DC microgrids . By this solution, using a predetermined power‐voltage curve for each source, all sources know their exact share of power per each voltage of the DC microgrid.…”
Section: Principles Of the Voltage Control In Direct Current Microgridsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, they suffer from low reliability and high cost. Another solution is the application of the voltage of DC microgrids . By this solution, using a predetermined power‐voltage curve for each source, all sources know their exact share of power per each voltage of the DC microgrid.…”
Section: Principles Of the Voltage Control In Direct Current Microgridsmentioning
confidence: 99%
“…Reference presents a general voltage control method that needs no telecommunication at the expense of the increase of complexities of the introduced voltage control method. Many researches apply droop technique or DC bus signaling to control the voltage of DC microgrids. These general voltage control methods utilize the DC voltage of DC microgrids, instead of telecommunication, to do their job.…”
Section: Introductionmentioning
confidence: 99%
“…Considering these points, the existing distribution load flow methods used for conventional dc power systems cannot be applied to dc microgrids and distribution systems with DBS control methods. On the other hand, none of the literature dealing with DBS control methods proposed a proper load flow method for the dc power system.…”
Section: Introductionmentioning
confidence: 99%
“…This configuration results in high efficiency, high reliability, and no frequency or phase control requirements, when compared to the AC interconnection bus [7], [8]. Moreover, it has low distribution and transmission losses, low cost, the possibility to operate across long distances and it does not use transformers, in turn leading to volume and cost reduction [2].…”
Section: Introductionmentioning
confidence: 99%