2021
DOI: 10.1109/access.2021.3115122
|View full text |Cite
|
Sign up to set email alerts
|

DC-Offset Compensation for Three-Phase Grid-Tied SPV-DSTATCOM Under Partial Shading Condition With Improved PR Controller

Abstract: This work deals with a single-stage three-phase grid connected solar photovoltaic-distribution static compensator (SPV-DSTATCOM) under partial shading condition (PSC). During PSC, the SPV-DSTATCOM is connected with the distribution network to solve issues like active current sharing, reactive power control, and harmonic elimination. The conventional Proportional Resonant (PR) controller behaves as a notch filter at resonance frequency with high gain in magnitude, and it has very little dc-offset rejection capa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 32 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…The updated weight in ( 12) is modified to weighted values corresponding to the active power components, and the reactive components are generated as (20).…”
Section: Proposed Dstatcom Control Structurementioning
confidence: 99%
See 1 more Smart Citation
“…The updated weight in ( 12) is modified to weighted values corresponding to the active power components, and the reactive components are generated as (20).…”
Section: Proposed Dstatcom Control Structurementioning
confidence: 99%
“…Adaptive control strategies have the capability of updating their parameters as a result of disturbances in the system. There are some weight-based approaches that include adaptive recursive inverse [20], neural network-based adaptive control approach [21], frequency-adaptive fractional order repetitive control [22], affine projection-like algorithm [23], and echo state-based control techniques [24]. However, the LMS algorithm [25] only updates the weights based on a single input vector.…”
Section: Introductionmentioning
confidence: 99%
“…where v t = 2 3 u 2 pa + u 2 pb + u 2 pc represent the amplitude of the terminal voltage. Equation (17) can also be used to estimate the quadrature unit template (u qa , u qb , u qc ) in (18).…”
Section: ) Unit Template Generationmentioning
confidence: 99%
“…The prime objective of grid-integrated SPV-DSTATCOM is to feed active as well as reactive power within the system in the presence of solar radiation [18], [19]. Apart from that, without solar radiation, this injects the harmonic compensation power needed by the load named as DSTATCOM.…”
Section: Introductionmentioning
confidence: 99%
“…The estimated frequency is erroneous because the low frequency component is superimposed on the average value. An improved PR controller-based SOGI-FLL is developed in [30] to address DC offset. However, it is less effective during highly dynamic load conditions.…”
Section: Introductionmentioning