2018
DOI: 10.1007/s40565-017-0371-3
|View full text |Cite
|
Sign up to set email alerts
|

Damping control for a target oscillation mode using battery energy storage

Abstract: In this paper, a battery energy storage system (BESS) based control method is proposed to improve the damping ratio of a target oscillation mode to a desired level by charging or discharging the installed BESS using local measurements. The expected damping improvement by BESS is derived analytically for both a single-machineinfinite-bus system and a multi-machine system. This BESS-based approach is tested on a four-generator, twoarea power system. Effects of the power converter limit, response time delay, powe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(16 citation statements)
references
References 22 publications
0
16
0
Order By: Relevance
“…Finally, the power output of the VSG is given as ref. [27]: PnormalES=Pnormalref1+TES.s,0.28em0,0.28emSOC<SOnormalCnormalmax0.28emnormalandPnormalref<0SOC>SOnormalCnormalminandPnormalref>0otherwise, PnormalESPES,0.28emnormalmin,PES,0.28emnormalmax,Pnormalref=JnormalVIs+DnormalVIΔf.…”
Section: Energy Storage and Virtual Synchronous Generator Modelmentioning
confidence: 99%
“…Finally, the power output of the VSG is given as ref. [27]: PnormalES=Pnormalref1+TES.s,0.28em0,0.28emSOC<SOnormalCnormalmax0.28emnormalandPnormalref<0SOC>SOnormalCnormalminandPnormalref>0otherwise, PnormalESPES,0.28emnormalmin,PES,0.28emnormalmax,Pnormalref=JnormalVIs+DnormalVIΔf.…”
Section: Energy Storage and Virtual Synchronous Generator Modelmentioning
confidence: 99%
“…Generally speaking, automatic voltage regulators (AVR) on generators [21], FACTS equipment (e.g., SVC, static synchronous compensator) [8], HVDC [27], inverter-based power source (e.g., energy storage, doubly-fed induction generator, photovoltaic) [28], [29] all can be used for damping LFOs. Hence, the input signal of the power system model for a WADC design can be the corresponding auxiliary input of these above devices.…”
Section: A Control Loop Selectionmentioning
confidence: 99%
“…In existing literature, BESSs are proposed to mitigate lowfrequency natural oscillations as actuators [16]- [19], but not forced oscillations. For instance, optimal placement and control parameters of BESSs are determined by the mixedinteger Particle Swarm Optimization algorithm to improve the damping of power system natural oscillations in [18]. In [19], a coordinated control of wind farms and BESSs is proposed to suppress inter-area natural oscillations.…”
Section: Introductionmentioning
confidence: 99%