Advances in Chemical Sensors 2012
DOI: 10.5772/33157
|View full text |Cite
|
Sign up to set email alerts
|

Coumarin-Derived Fluorescent Chemosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(31 citation statements)
references
References 146 publications
0
31
0
Order By: Relevance
“…It is well known that addition of electron withdrawing substitutents at the 3-position of 7-aminocoumarins produce large bathochromic shifts in the absorption maximum 12 . For example, 3-nitro-DEAC ( 1 ) not only has a large absorption maximum at 470 nm, but an extremely low minimum in the 340-360 nm-range (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…It is well known that addition of electron withdrawing substitutents at the 3-position of 7-aminocoumarins produce large bathochromic shifts in the absorption maximum 12 . For example, 3-nitro-DEAC ( 1 ) not only has a large absorption maximum at 470 nm, but an extremely low minimum in the 340-360 nm-range (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Another interesting phenomenon is the unaffected fluorescence spectra of 1e between pH 3.3 and 11.0. It is well known that the electron donating groups (such as amino-group) substituted on coumarin into electrondeficient positions (positions 4, 5 and 7) will increase the intramolecular electron transfer and thus enhance the fluorescence intensity of coumarin derivatives [12,27]. At the same time an electron-deficient 2-hydroxybenzyl substitution on the amino-group can decrease this effect.…”
Section: Proton Dissociation Processes and Calculated Lipophilicity Omentioning
confidence: 99%
“…Coumarin derivatives exhibit strong fluorescence in the visible wavelength region which is usually significantly influenced by the surrounding medium [27]. At the same time HSA contains a single tryptophan (Trp 214) residue near to site I that is responsible for the majority of the intrinsic fluorescence of the protein.…”
Section: Introductionmentioning
confidence: 99%
“…The combined organic layers were dried over Na 2 SO 4 and concentrated under reduced pressure to afford a crude product, which was purified by column chromatography, using silica gel eluted with 30 % ethyl acetate in hexane, to give monomer 3, as a brown solid. ( 4 .5H 2 O (10 mol% of monomer 3) in a minimum amount of water were also added to the mixture. After stirring at room temperature for 24 h, the solvent was removed under reduced pressure and the residue stirred in water (50 mL) and isolated by vacuum filtration.…”
Section: Synthesis Of Monomermentioning
confidence: 99%
“…These features allow coumarin derivatives to have a wide range of applications in the photoelectronic, medicinal and biological fields, as well as in industry as fluorescent probes. [1][2][3][4] Furthermore, substituents manipulation on the coumarin backbone can lead to a fine-tuning of its emission properties. 5 One of the strategies that have been used to improve the emission properties of coumarin is to include a 1,2,3-triazole ring in the structure which is formed by means of a Cu(I)-catalyzed fluorogenic azide-alkyne 1,3-dipolar cycloaddition, a typical click reaction.…”
Section: Introductionmentioning
confidence: 99%