1982
DOI: 10.1161/01.str.13.3.386
|View full text |Cite
|
Sign up to set email alerts
|

Correlation of peak Doppler frequency with lumen narrowing in carotid stenosis.

Abstract: SUMMARY The peak Doppler-shifted frequency and degree of lumen narrowing were compared in 75 cervical carotid stenoses. Peak frequency was not found to precisely indicate severity of stenosis, but it was possible to divide stenoses into four ranges of severity on the basis of peak frequency. Peak frequencies of less than 5 KHz, in most instances, indicated stenoses of less than 50% decrease in lumen area. Frequencies from 5 to 8 KHz were generally associated with stenoses of 50-75% decrease in lumen area, and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
10
0
8

Year Published

1984
1984
2002
2002

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(20 citation statements)
references
References 13 publications
2
10
0
8
Order By: Relevance
“…34,35,52,53 The scanning and reading protocols were identical to those used in the Cardiovascular Health Study. 54 All studies were recorded on super VHS tape and sent weekly to a central reading center.…”
Section: Methodsmentioning
confidence: 99%
“…34,35,52,53 The scanning and reading protocols were identical to those used in the Cardiovascular Health Study. 54 All studies were recorded on super VHS tape and sent weekly to a central reading center.…”
Section: Methodsmentioning
confidence: 99%
“…The broadening of the frequency spectrum is usually classified in different categories either on the basis of the presence or absence of a signal-free "window" during peak systole, or on the basis of an increase in systolic peak frequency. 31 -" A more quantitative approach to express spectrum broadening was described by Bodily and coworkers 34 who used the ratio of the difference and sum of the maximum and minimum frequency at peak systole in addition to the mean frequency, again at peak systole.…”
Section: External Carotid Artery Ecamentioning
confidence: 99%
“…18 High-resolution B-mode carotid ultrasonography was performed with Toshiba SSA-270A imaging units (Toshiba America Medical Systems) to provide an index of atherosclerosis. 11,12,19,20 The scanning and reading protocols were identical to those used in the Cardiovascular Health Study. 15 A bilateral assessment of the wall thickness was made in the internal carotid artery (ICA) and common carotid artery (CCA).…”
mentioning
confidence: 99%