2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI 2017
DOI: 10.1109/icici-bme.2017.8537768
|View full text |Cite
|
Sign up to set email alerts
|

Control System for DC Motor Based Micro Air Pump to Simulate Oscillograph of Blood Pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
0
0
3

Year Published

2019
2019
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 4 publications
0
0
0
3
Order By: Relevance
“…This research was compared with the research of Nico Antonio Santoso et al who conducted research on the NIBP simulator which had a deficiency in the 60/30 setting with an error of 6.67%, whereas in this study at the 60/30 setting the resulting error was 5.64% which is smaller than Antonio's research [15]. According the research by A Darwongso et al, a blood pressure simulator was developed using the MPX5100 pressure sensor, while in my research using the MPX5050 pressure sensor where the resulting values are more accurate [17].…”
Section: Discussionmentioning
confidence: 61%
See 1 more Smart Citation
“…This research was compared with the research of Nico Antonio Santoso et al who conducted research on the NIBP simulator which had a deficiency in the 60/30 setting with an error of 6.67%, whereas in this study at the 60/30 setting the resulting error was 5.64% which is smaller than Antonio's research [15]. According the research by A Darwongso et al, a blood pressure simulator was developed using the MPX5100 pressure sensor, while in my research using the MPX5050 pressure sensor where the resulting values are more accurate [17].…”
Section: Discussionmentioning
confidence: 61%
“…However, it is important to acknowledge the limitations of this study, as it still exhibited an error rate of 6.67% specifically at the preset blood pressure level of 60/30. While the use of a micro air pump and pressure sensor represents a notable advancement in the methodology, the observed error suggests the presence of inaccuracies or imprecisions in the measurement process [15] [16]. Then in 2019, A Darwongso et al, conducted a study entitled Blood Pressure Simulator: Minimizing the Effects of Inflation and Deflation Rates on Oscillation Simulations.…”
Section: Introductionmentioning
confidence: 99%
“…Namun untuk memberikan hasil yang sama, diperlukan program (firmware) simulasi berbeda untuk tiap merek. Ini berbeda dari pengujian dengan simulator NIBP komersial, yang menghasilkan hasil yang sama terlepas dari semua jenis atau merek monitor NIBP (Santoso & Ughi, 2017).…”
Section: Pendahuluanunclassified
“…Gagasan dari metode pada program yang digunakan oleh kedua penelitian tersebut di atas adalah dengan menemukan beberapa target osilasi untuk tiap nilai tekanan tertentu (Dewanto, 2016) (Santoso & Ughi, 2017). Ilustrasi pada Gambar 1 menjelaskan bagaimana nilai selisih ditentukan dari suatu grafik osilasi.…”
Section: Pendahuluanunclassified
See 1 more Smart Citation