Abstract: ABSTRAKSimulator tekanan darah biasa digunakan sebagai nilai referensi dalam mengevaluasi tensimeter otomatis (NIBP monitor). Penelitian sebelumnya menunjukkan bahwa simulator tekanan darah dapat dibuat dengan menggunakan micro air pump berbasis motor dc sebagai aktuator. Namun, hasil simulasi yang dihasilkan berbeda untuk setiap merek tensimeter. Hasil analisa menunjukkan bahwa laju inflasi dan deflasi yang berbeda mempengaruhi karakteristik simulasi. Studi ini bertujuan untuk mengembangkan firmware simulator… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 4 publications
0
0
0
Order By: Relevance
“…This research was compared with the research of Nico Antonio Santoso et al who conducted research on the NIBP simulator which had a deficiency in the 60/30 setting with an error of 6.67%, whereas in this study at the 60/30 setting the resulting error was 5.64% which is smaller than Antonio's research [15]. According the research by A Darwongso et al, a blood pressure simulator was developed using the MPX5100 pressure sensor, while in my research using the MPX5050 pressure sensor where the resulting values are more accurate [17]. Similar to research conducted by A. Aditya et al This study aims to measure blood pressure using a noninvasive approach, particularly the oscillometry method [23].…”
Section: Discussionmentioning
confidence: 55%
See 1 more Smart Citation
“…This research was compared with the research of Nico Antonio Santoso et al who conducted research on the NIBP simulator which had a deficiency in the 60/30 setting with an error of 6.67%, whereas in this study at the 60/30 setting the resulting error was 5.64% which is smaller than Antonio's research [15]. According the research by A Darwongso et al, a blood pressure simulator was developed using the MPX5100 pressure sensor, while in my research using the MPX5050 pressure sensor where the resulting values are more accurate [17]. Similar to research conducted by A. Aditya et al This study aims to measure blood pressure using a noninvasive approach, particularly the oscillometry method [23].…”
Section: Discussionmentioning
confidence: 55%
“…The identified error, although relatively small, indicates the presence of minor inaccuracies in the blood pressure simulation process. It is crucial to address this error to ensure the reliability and accuracy of the simulator's output [17] [18] [19] . In 2017, N. Shahid conducted research with the title Comparative Analysis and Accuracy of a Devised Automated Non Invasive Blood Pressure Monitor Based on Oscillometric Method.…”
Section: Introductionmentioning
confidence: 99%