1981
DOI: 10.1116/1.571159
|View full text |Cite
|
Sign up to set email alerts
|

Contactless electrical testing of large area specimens using electron beams

Abstract: An e-beam test system has been developed to detect opens and shorts in three-dimensional networks of conductors embedded in a dielectric matrix. The specimens, which measure up to 100×100 mm, are tested electrically without making physical contact and without mechanical stepping. The system comprise two flood beams and a focused probe beam deflected over the full specimen area at a resolution of better than 3000 lines at 1–2 kV beam energy. One flood gun is located at the rear, the other at the front of the sp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

1983
1983
2008
2008

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 0 publications
0
19
0
Order By: Relevance
“…VC-SEM, as described here, involves externally biasing the substrate (sometimes called VC Type 2). VC Types 1 and 2 have been used in microelectronics for failure location in interconnects [16]. An associated mechanism (sometimes called VC Type 3) has been used to image dopant concentrations [17] at inorganic bulk material interfaces.…”
Section: Introductionmentioning
confidence: 99%
“…VC-SEM, as described here, involves externally biasing the substrate (sometimes called VC Type 2). VC Types 1 and 2 have been used in microelectronics for failure location in interconnects [16]. An associated mechanism (sometimes called VC Type 3) has been used to image dopant concentrations [17] at inorganic bulk material interfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 12 shows how DFI compares to other electron-beam systems, when used in the full die view mode. Also shown is the contactless testing method developed at IBM for testing "thermoconduction modules" [21].…”
Section: Electron Optics Ad Voltage Contrastmentioning
confidence: 99%
“…This is illustrated in Fig. 13, which was taken from Pfeiffer et al (1981), and shows schematically the connector pattern in a multilayer packaging substrate. The matrix in this case is ceramic.…”
Section: Specimen Structuresmentioning
confidence: 99%
“…In the approaches reported by Sebeson (1973), and Gill et al (1979) a single electron beam is used, and t~e acceleration voltage is switched between the charging and the read phase. Engelke (1974) operates with two individually controlled beams, and Pfeiffer et al (1981) use flood beams and one probe beam simultaneously or in sequence.…”
Section: Operational Conditionsmentioning
confidence: 99%