2007
DOI: 10.1007/s00271-007-0085-9
|View full text |Cite
|
Sign up to set email alerts
|

Construction, installation, and performance of two repacked weighing lysimeters

Abstract: Weighing lysimeters are the standard method for directly measuring evapotranspiration (ET). This paper discusses the construction, installation, and performance of two (1.52 m × 1.52 m × 2.13-m deep) repacked weighing lysimeters for measuring ET of corn and soybean in West Central Nebraska. The cost of constructing and installing each lysimeter was approximately US $12,500, which could vary depending on the availability and cost of equipment and labor. The resolution of the lysimeters was 0.0001 mV V −1 , whic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
28
0
5

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 34 publications
(36 reference statements)
0
28
0
5
Order By: Relevance
“…Since it is possible to make measurements at 10 min interval, the resolution of 0.027 mm of water corresponds with an ET of 0.162 mm h -1 . The overall resolution of a lysimeter system is dependent on the capability of the data logger in terms of voltage resolution and its significant digits (Payero and Irmak, 2008). However, these are not considered further as effective calibration and deviation minimisation schemes described here incorporated these features of the measurement system.…”
Section: General Discussion and Conclusionmentioning
confidence: 99%
See 3 more Smart Citations
“…Since it is possible to make measurements at 10 min interval, the resolution of 0.027 mm of water corresponds with an ET of 0.162 mm h -1 . The overall resolution of a lysimeter system is dependent on the capability of the data logger in terms of voltage resolution and its significant digits (Payero and Irmak, 2008). However, these are not considered further as effective calibration and deviation minimisation schemes described here incorporated these features of the measurement system.…”
Section: General Discussion and Conclusionmentioning
confidence: 99%
“…We used five sample load cells to investigate the hysteresis effects using six separate loads within 0-15.7 kg. Regression lines were fitted to these data in a way similar to that shown by Payero and Irmak (2008). Since there was no significant difference in signal during loading and unloading conditions for these five load cells, there was an overlap of regression lines fitted to signal vs. load data (graph not shown).…”
Section: Treatmentsmentioning
confidence: 99%
See 2 more Smart Citations
“…The field is flat and is 5 ha in size. Most lysimeter facilities are located in fields that do not exceed this area (Allen & Fisher, 1990;Jia (e.g., van Bavel & Myers, 1962), they are still considered one of the most accurate methodologies to study the return of water to the atmosphere by the combined processes of evaporation and transpiration (Malone et al, 2000), and are the standard method to directly measure ET c (Reicosky et al, 1983;Payero & Irmak, 2008).…”
Section: Field Characteristicsmentioning
confidence: 99%