2020
DOI: 10.1002/ccd.29395
|View full text |Cite
|
Sign up to set email alerts
|

Computer‐assisted valve in valve in a deteriorated Mosaic valve using a library of bioprostheses

Abstract: Valve‐in‐valve (ViV) procedures have emerged from an off‐label procedure to a safe and efficient alternative to redo aortic valve replacement in the treatment of symptomatic structural valve deterioration (SVD). During ViV procedures, optimal placement of the transcatheter heart valve (THV) inside the degenerated bioprosthesis is of paramount importance regarding complications such as device embolization, coronary obstruction, periprosthetic regurgitation, residual gradients, and mitral valve injury, but also … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 9 publications
0
1
0
Order By: Relevance
“…The 3D/2D fusion of CT-scan derived images onto fluoroscopic images have been used in the context of TAVI-ViV [ 5 ] . Superimposing a representation of the LVOT during the procedure on live fluoroscopy images (augmented imaging) might help visualizing its relationship with the balloon-expandable THV and guide valve deployment.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The 3D/2D fusion of CT-scan derived images onto fluoroscopic images have been used in the context of TAVI-ViV [ 5 ] . Superimposing a representation of the LVOT during the procedure on live fluoroscopy images (augmented imaging) might help visualizing its relationship with the balloon-expandable THV and guide valve deployment.…”
Section: Discussionmentioning
confidence: 99%
“…Second, we match the degenerate BVS-mesh and its correspondent undeteriorated BVS-mesh from our library of bioprosthesis [ 5 ] ( Figure 1A ). We applied an iterative closest point algorithm to align the two BVS-meshes.…”
Section: Methodsmentioning
confidence: 99%
“…Usage of inverted TAVR prosthesis in TMVIV has been widely reported ( 11 , 12 ). Mid-term reports from multiple cohorts have shown acceptable results using SAPIEN 3 [(Edwards Lifesciences), Melody (Medtronic, Minneapolis, MN), Lotus (Boston Scientific, Natick, MA, USA) and Direct Flow (Direct Flow Medical Inc., Santa Rosa, CA, USA)] ( 13 17 ).…”
Section: Introductionmentioning