1992
DOI: 10.1097/00003086-199203000-00027
|View full text |Cite
|
Sign up to set email alerts
|

Computed Tomography Measurement of Acetabular Cup Anteversion and Retroversion in Total Hip Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
31
0
4

Year Published

2004
2004
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(35 citation statements)
references
References 0 publications
0
31
0
4
Order By: Relevance
“…Although there is no gold standard to validate either measurement method, the discrepancy between CT and cross-table lateral films casts doubt on the radiographic measurements, given the low ICC for serial plain film measurements discussed above and correction of pelvic tilt and rotation using reformatted CT. Mian et al [22] provided an early description of using CT after THA to measure acetabular component anteversion. Although describing their method of anteversion calculation using CT as ''highly accurate'' based on an in vitro model, they provided no data to support this claim.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although there is no gold standard to validate either measurement method, the discrepancy between CT and cross-table lateral films casts doubt on the radiographic measurements, given the low ICC for serial plain film measurements discussed above and correction of pelvic tilt and rotation using reformatted CT. Mian et al [22] provided an early description of using CT after THA to measure acetabular component anteversion. Although describing their method of anteversion calculation using CT as ''highly accurate'' based on an in vitro model, they provided no data to support this claim.…”
Section: Discussionmentioning
confidence: 99%
“…1). Prior studies have confirmed CT as an accurate method to determine anteversion of acetabular cups after THA [22,27]. In addition, the CT scan provided measurement of femoral stem version that was not used for this study.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Using CT-based calculation, an exact reference plane can be defined. Such reference provides highly accurate information of the three-dimensional cup position [15,19,20]. In the current study, orientation of the acetabular components was determined using a CT scan of the pelvis.…”
Section: Introductionmentioning
confidence: 99%
“…In Abhängigkeit von Einstellung des Zentralstrahles, Lagerung des Patienten, Beckenkippung und Implantatposition ergeben sich Fehlerbreiten von mehr als 10° [15,16,17]. Die Genauigkeitsanalyse eines Navigationssystemes für die Hüftendoprothetik durch die Positionsbestimmung der real implantierten Pfanne in den postoperativen Becken-Computertomographien mit Hilfe der CT-basierten Planungssoftware ist daher gegenwärtig als Kontrollverfahren der Wahl anzusehen [1,7].…”
Section: Diskussionunclassified