2014
DOI: 10.1061/(asce)st.1943-541x.0000922
|View full text |Cite
|
Sign up to set email alerts
|

Computational Simulation of a Full-Scale, Fixed-Base, and Isolated-Base Steel Moment Frame Building Tested at E-Defense

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
29
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 16 publications
(29 citation statements)
references
References 20 publications
0
29
0
Order By: Relevance
“…For example, for BI buildings with a linear isolation system, Ryan and Polanco 27 showed that using the KD approach and computing β k based on the fundamental mode of the fixed-base superstructure would result in a reasonable specification of damping to the isolated mode. An evaluation of the results of several others studies on BI buildings, available in the literature, can readily reveal the significance of the highfrequency content of floor acceleration responses (eg, see the floor spectra illustrated for tested BI buildings in 28,30 and for numerical BI models in [34][35][36] ). Kitayama and Constantinou 31 suggested a solution for cases in which the global damping matrix was constructed based on modal damping ratios.…”
Section: Figurementioning
confidence: 99%
“…For example, for BI buildings with a linear isolation system, Ryan and Polanco 27 showed that using the KD approach and computing β k based on the fundamental mode of the fixed-base superstructure would result in a reasonable specification of damping to the isolated mode. An evaluation of the results of several others studies on BI buildings, available in the literature, can readily reveal the significance of the highfrequency content of floor acceleration responses (eg, see the floor spectra illustrated for tested BI buildings in 28,30 and for numerical BI models in [34][35][36] ). Kitayama and Constantinou 31 suggested a solution for cases in which the global damping matrix was constructed based on modal damping ratios.…”
Section: Figurementioning
confidence: 99%
“…18,19 This interaction between the horizontal and vertical response of the structure was observed to be strongest in the TPB configuration, yet it was evident in all 3 configurations as the floor accelerations were amplified during 3D excitations compared with 2D. The behavior was replicated by analysis and identified as a horizontal-vertical (H-V) coupling effect between the horizontal and vertical response of the specimen tested, both in the fixed-base and in the isolated configurations.…”
mentioning
confidence: 92%
“…The behavior was replicated by analysis and identified as a horizontal-vertical (H-V) coupling effect between the horizontal and vertical response of the specimen tested, both in the fixed-base and in the isolated configurations. 18,19 This interaction between the horizontal and vertical response of the structure was observed to be strongest in the TPB configuration, yet it was evident in all 3 configurations as the floor accelerations were amplified during 3D excitations compared with 2D. In the past, analytical studies have reported an increase of several response parameters of structures isolated with friction bearings subjected to 3D excitation in comparison with 2D.…”
mentioning