Comparison of 11 Human Insulin Assays: Implications for Clinical Investigation and Research

Abstract: Background: The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. Methods: In 2004, we compared 11 commercially available insulin assays by analyzing 150 serum samples (99 fasting/51 postprandial) from study participants with various degrees of glucose intolerance (exclusions being type 1 diabetes, insulin treatment, or presence of insuli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
113
1
3

Year Published

2007
2007
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 146 publications
(121 citation statements)
references
References 30 publications
4
113
1
3
Order By: Relevance
“…Insulin concentrations will vary depending on analytical method, including the use of plasma or serum. 25,26 Although some discrepancies may have resolved with improving technologies, they should be considered if older studies are referenced. Participant factors such as age, sex, body fat distribution and health status may also affect insulin sensitivity.…”
Section: Discussionmentioning
confidence: 99%
“…Insulin concentrations will vary depending on analytical method, including the use of plasma or serum. 25,26 Although some discrepancies may have resolved with improving technologies, they should be considered if older studies are referenced. Participant factors such as age, sex, body fat distribution and health status may also affect insulin sensitivity.…”
Section: Discussionmentioning
confidence: 99%
“…Part of the motivation behind the project was the known variability between immunoassays and even between the same immunoassay performed at multiple sites (23)(24)(25)(26)(27)(28), including for IGF-1 (3 ). Those reports were supported by the data available from the College of American Pathologists (CAP) proficiency testing program for IGF-1 (BGS survey), which from September 2011 to March 2013 demonstrated interlaboratory variability up to 33.5% CV.…”
Section: Discussionmentioning
confidence: 99%
“…Além do mais, foi utilizado um ensaio para insulina com ausência de reação cruzada com pró-insulina, o que garante maior confiabilidade das determinações plasmáticas. Apesar da praticidade na utilização do HOMA-IR na pesquisa, quando comparado ao clamp; na prática clínica, a determinação da insulinemia de jejum conta com as desvantagens da ausência de padronização entre os laboratórios, tanto no que diz respeito ao método quanto ao ensaio utilizado 24 . Em relação ao custo, são dosagens relativamente caras e indisponíveis em muitos serviços de saúde.…”
Section: Figura 1 -Curva Roc Para Os Indicadores Bioquímicos Do Perfiunclassified