2012 International Conference on Applied and Theoretical Electricity (ICATE) 2012
DOI: 10.1109/icate.2012.6403401
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study on power transformers vegetable and mineral oil ageing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 11 publications
1
11
0
Order By: Relevance
“…The test results showed that the use of vegetable oil improved the performance of transformers, prolonged useful life, lowered rates of failure.Jung-II Jeong et al [52] thermally aged transformer filled with vegetable oil and mineral oil and concluded results that vegetable oil have better insulation characteristics as compared to the mineral oil. Alexandra Ciuriuc et al [53] presented comparative study related to the ageing of vegetable and mineral oils used in power transformers. The samples of vegetable and mineral oil were accelerated thermally aged and their dielectric properties (real part of complex permittivity, dissipation factor and resistivity) were found at different ageing times.…”
Section: Historic Evolution Of Vegetable Oil As Transformer Oilmentioning
confidence: 99%
“…The test results showed that the use of vegetable oil improved the performance of transformers, prolonged useful life, lowered rates of failure.Jung-II Jeong et al [52] thermally aged transformer filled with vegetable oil and mineral oil and concluded results that vegetable oil have better insulation characteristics as compared to the mineral oil. Alexandra Ciuriuc et al [53] presented comparative study related to the ageing of vegetable and mineral oils used in power transformers. The samples of vegetable and mineral oil were accelerated thermally aged and their dielectric properties (real part of complex permittivity, dissipation factor and resistivity) were found at different ageing times.…”
Section: Historic Evolution Of Vegetable Oil As Transformer Oilmentioning
confidence: 99%
“…As shown in these figures, it is clear that the peak absorbance value of the O-H functional group located close to 3329 cm −1 decreases with aging due to the oxidation process. The products of degradation of cellulose paper are CO, CO2, H2O, H2, CH4, and furans, which are dissolved in the mineral oil [28]. During thermal aging, the cleavage of cellulose chains involves an O-H functional group.…”
Section: Fourier Transform Infrared (Ftir) Spectroscopy Analysis Of Tmentioning
confidence: 99%
“…Because IMO is derived from petroleum, a non-renewable resource, new alternatives for insulating fluids for the electrical sector have been sought. Insulating natural esters (INEs) show faster biodegradability than IMO and are derived from renewable resources; thus, INEs are strong candidates for replacing IMO [3] . Solid insulation is performed by insulating paper based on 90% cellulose coupled with hemicellulose, lignin and traces of pentose; this insulating paper is fundamentally important because it cannot be replaced while a transformer is in service, and thus, the paper determines the useful lifetime of the equipment [4] .…”
Section: Introductionmentioning
confidence: 99%