2015
DOI: 10.1039/c5ra07247f
|View full text |Cite
|
Sign up to set email alerts
|

Comparative investigation of spectroelectrochemical and biosensor application of two isomeric thienylpyrrole derivatives

Abstract: In the present work, we performed a comparative investigation of spectroelectrochemical and biosensor application of two isomeric thienylpyrrole derivatives.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
31
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 46 publications
(33 citation statements)
references
References 36 publications
0
31
0
1
Order By: Relevance
“…In order to the fabrication of Cu@PCR electrode, firstly, conducting polymer matrix has been prepared on the bare graphite electrode. For this reason, the bare graphite electrode has been polished and washed thoroughly with distilled water [30]. The electrochemical polymerization of the CR monomer has been performed by the CV technique, which was depicted the reversibility of electron transfer during the polymerization.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to the fabrication of Cu@PCR electrode, firstly, conducting polymer matrix has been prepared on the bare graphite electrode. For this reason, the bare graphite electrode has been polished and washed thoroughly with distilled water [30]. The electrochemical polymerization of the CR monomer has been performed by the CV technique, which was depicted the reversibility of electron transfer during the polymerization.…”
Section: Resultsmentioning
confidence: 99%
“…Another important factor that limits the applicability of the prepared sensor platform in various samples is the presence of compounds that can interfere. Phenolic compounds, ethanol, ascorbic acid and other oxidizable compounds often coexist with glucose in real samples such as beverages and possibly interfere with the detection of glucose [30].…”
Section: Resultsmentioning
confidence: 99%
“…İlk olarak, ditiyenil pirol türevi (SNS) literatürdeki yöntem kullanılarak sentezlenmiştir [29]. Daha sonra PMA sentezi, 4-(2,5-di(tiyofen-2-yl)-1H-pirol-1-yl)anilin (SNS) ve 1-pirenkarboksialdehit (PC)'in kondenzasyon reaksiyonuyla elde edilmiştir.…”
Section: A Monomer Sentezi̇unclassified
“…Fc has lower oxidation potential compared to oxygen so that Fc will oxidize and not cause other biological material to oxidize (Paul, Borreli, Bouyanfif, Gottis, & Sauvage, 2019). It was reported by Ayranci, Demirkol, Ak, & Timur (2015), Fc was used as a redox mediator during the electrochemical measurements for glucose.…”
Section: Introductionmentioning
confidence: 99%