2013
DOI: 10.1016/j.optlaseng.2013.05.005
|View full text |Cite
|
Sign up to set email alerts
|

Common-path interferometer with four simultaneous phase-shifted interferograms using ronchi grating and cube beamsplitter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…In general, it is required to combine the phase-shifting technique to retrieval phase .In 1997, the group of Yamaguchi [11] first introduced the phase-shift method to the on-axis digital holography and got an experimental verification. Then, many other phase-shift digital holographic phase microscopy techniques have been successively reported [12][13][14][15], such as Awatsuji and etc from 2004 to 2006, respectively, put forward parallel quasi four steps [12] and three phase shift holographic technology [13] to realized 3D images of a object. In 2012, Samsheerali [15] reported a coaxial phase-shift digital holographic technology with the help of a diffraction grating phase, which realized the high stability of the quantitative phase imaging.…”
Section: Introductionmentioning
confidence: 99%
“…In general, it is required to combine the phase-shifting technique to retrieval phase .In 1997, the group of Yamaguchi [11] first introduced the phase-shift method to the on-axis digital holography and got an experimental verification. Then, many other phase-shift digital holographic phase microscopy techniques have been successively reported [12][13][14][15], such as Awatsuji and etc from 2004 to 2006, respectively, put forward parallel quasi four steps [12] and three phase shift holographic technology [13] to realized 3D images of a object. In 2012, Samsheerali [15] reported a coaxial phase-shift digital holographic technology with the help of a diffraction grating phase, which realized the high stability of the quantitative phase imaging.…”
Section: Introductionmentioning
confidence: 99%
“…Traditional interferometers [5][6][7][8], such as the Mach-Zehnder or Michelson interferometers, are subject to error because of environmental effects such as vibrations, air turbulence, and temperature on the wide separated paths of the object and reference beam. Thus, common-path interferometers [9][10][11][12][13][14][15][16][17] are of growing interests due to the inherent robustness in the setup, where the object and reference beam travel almost in the same path. For example, Shaked [13] proposed an off-axis common-path interferometer using a modified Michelson architecture.…”
Section: Introductionmentioning
confidence: 99%
“…A two-window common-path interferometer with simultaneous phase shifting [19][20][21][22] has been proposed recently; it includes two windows in the object plane and a grating in the Fourier plane of a 4f system, respectively, and uses polarization elements to achieve phase shifting. These methods can realize high-stability and low-noise real-time measurement, but the utilization of FOV is decreased.…”
Section: Introductionmentioning
confidence: 99%