2009
DOI: 10.1159/000202977
|View full text |Cite
|
Sign up to set email alerts
|

Combined Diffuse Light Reflectance and Electrical Impedance Measurements as a Navigation Aid in Deep Brain Surgery

Abstract: Aim: The aim of this study is to assess reflected light intensity combined with impedance as a navigation aid during stereotactic neurosurgery. Methods: During creation of 21 trajectories for stereotactic implantation of deep brain stimulation electrodes in the globus pallidus internus or subthalamus (zona incerta or subthalamic nucleus), impedance at 512 kHz and reflected light intensity at 780 nm were measured continuously and simultaneously with a radio frequency electrode containing optical fibres. The sig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
38
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
3
3

Relationship

4
2

Authors

Journals

citations
Cited by 29 publications
(41 citation statements)
references
References 31 publications
(28 reference statements)
3
38
0
Order By: Relevance
“…A previously developed optical system was used for the intracerebral measurements [10,11]. It consists of a spectrometer (AvaSpec-2048-2, Avantes BV, The Netherlands) and a white lamp (AvaLight-Hal-S, Avantes BV, The Netherlands).…”
Section: Optical Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…A previously developed optical system was used for the intracerebral measurements [10,11]. It consists of a spectrometer (AvaSpec-2048-2, Avantes BV, The Netherlands) and a white lamp (AvaLight-Hal-S, Avantes BV, The Netherlands).…”
Section: Optical Systemmentioning
confidence: 99%
“…Recently, optical methods for intracerebal guidance and verification of target structures and pre-planned trajectories have been presented [8][9][10][11][12]. These are based on differentiation of grey, light grey and white matter by diffuse light scattering using wavelengths in the near infrared region where the impact of light absorption is very small for short fibre separations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Up to date, the spectral measurements during clinical implantations of DBS electrodes have been used by Giller and co-workers in more than 200 implantation procedures and also been compared with microelectrode recording [35]. The concept developed by Wårdell and colleagues, which is based on both laser Doppler perfusion monitoring (LDPM) [118] and diffuse reflection spectroscopy [2], have been clinically evaluated on more than 50 DBS lead implantations and compared to impedance recordings [58]. This group extracts curve data from specific wavelength intervals e.g.…”
Section: Optical Intracerebral Measurementsmentioning
confidence: 99%
“…The last section differs depending on the target area aimed at. For the GPi a characteristic "double peak", representing light intensity changes during insertion through the white lamina surrounding the Putamen, GPe and GPi has been identified [58] (Fig. 4).…”
Section: Optical Intracerebral Measurementsmentioning
confidence: 99%