Intracerebral quantitative chromophore estimation from reflectance spectra captured during deep brain stimulation implantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 18 publications
(27 citation statements)
references
References 37 publications
(29 reference statements)
1
26
0
Order By: Relevance
“…The absorption due to hemoglobin in the brain tissue is dependent on cerebral blood volume[54] and was calculated based on the volume fraction of the blood in the cerebral tissue, hemoglobin oxygen saturation of mixed arterio-venous vasculature, and the absorption coefficient of pure oxy and deoxyhemoglobin [55]. The molar concentration of oxidized and reduced CCO (in mM) were first obtained for the gray and white matter[56]. The absorption coefficient of 1mM of CCO was obtained [2] based on which the tissue absorption coefficient due to oxidized and reduced CCO was calculated.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The absorption due to hemoglobin in the brain tissue is dependent on cerebral blood volume[54] and was calculated based on the volume fraction of the blood in the cerebral tissue, hemoglobin oxygen saturation of mixed arterio-venous vasculature, and the absorption coefficient of pure oxy and deoxyhemoglobin [55]. The molar concentration of oxidized and reduced CCO (in mM) were first obtained for the gray and white matter[56]. The absorption coefficient of 1mM of CCO was obtained [2] based on which the tissue absorption coefficient due to oxidized and reduced CCO was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…The optical properties of the tissues in the head model vary significantly based on prior works. We selected a set of optical parameters from review literature[39][56][49]. We did not consider chromophores in the skin such as melanin, lipofuscin.…”
Section: Systematic Model Errorsmentioning
confidence: 99%
“…Such a procedure is often adopted in deep brain stimulation [42] and epilepsy surgery [43], where recording microelectrodes are implanted into deep brain structures. Fiber-based endoscopic imaging modalities, including optical coherence tomography [9], optical diffuse reflectance spectroscopy [44] and others, have been developed to guide the implantation. The guidance is realized by identifying tissue type in the vicinity of the electrode for localization, and most crucially by visualizing tissue ahead of the electrode to avoid penetrating any critical structures such as major vessels.…”
Section: Methodology and Limitationsmentioning
confidence: 99%
“…7(c). (49) With the help of the oxygenated hemoglobin (HbO 2 ) and deoxygenated hemoglobin (Hb) spectra from brain tissue, an estimation of the oxygen saturation (SO 2 ) can be achieved by curve fitting to known absorption spectra. The present work in the Linköping group focuses on improving the oxygen saturation algorithm for in vivo on line recording in brain tissue (50) in relation to, for example, traumatic brain injury in the neuro-intensive care unit, and thus also adaptation and implementation of the methods for monitoring of both microcirculation (12) and tissue oxygenation during brain surgery.…”
Section: Drs As a Navigational Tool During Stereotactic Neurosurgerymentioning
confidence: 99%