Imaging of tissue perfusion is important in assessing the influence of peripheral vascular disease on microcirculation. This paper reports on a laser Doppler perfusion imaging technique based on dynamic light scattering in tissue. When a laser beam sequentially scans the tissue (maximal area approximately 12 cm *12 cm), moving blood cells generate Doppler components in the back-scattered light. A fraction of this light is detected by a remote photodiode and converted into an electrical signal. In the signal processor, a signal proportional to the tissue perfusion at each measurement point is calculated and stored. When the scanning procedure is completed, the system generates a color-coded perfusion image on a monitor. A perfusion image is typically built up of data from 4,096 measurement sites, recorded during a time period of 4 min. This image has a spatial resolution of about 2 mm * 2 mm. A theory for the system inherent amplification factor dependence on the distance between individual measurement points and detector is proposed and correction measures are presented. The performance of the laser Doppler perfusion imager was evaluated using a flow simulator. The correlation coefficient between the estimated flow parameter and the perfusion through a mechanical flow simulator was calculated to r = 0.996. To assess the sampling depth of the laser beam, light scattering in tissue was simulated by a Monte Carlo technique. The average sampling depth for skin tissue was calculated to 200-240 microns, depending on the blood content.(ABSTRACT TRUNCATED AT 250 WORDS)
1 Abstract-Models and simulations are commonly used to study deep brain stimulation (DBS). Simulated stimulation fields are often defined and visualized by electric field isolevels or volumes of tissue activated (VTA). The aim of the present study was to evaluate the relationship between stimulation field strength as defined by the electric potential, V, the electric field, E, and the divergence of the electric field , and neural activation. Axon cable models were developed and coupled to finite element DBS models in 3D. Field thresholds (VT, ET, and VT) were derived at the location of activation for various stimulation amplitudes (1 to 5 V), pulse widths (30 to 120 µs), and axon diameters (2.0 to 7.5 µm). Results showed that thresholds for VT and VT were highly dependent on the stimulation amplitude while ET, were approximately independent of the amplitude for large axons. The activation field strength thresholds presented in this study may be used in future studies to approximate the VTA during model-based investigations of DBS without the need of computational axon models.
Background/Aims: Deep brain stimulation (DBS) is widely used to treat motor symptoms in patients with advanced Parkinson’s disease. The aim of this study was to investigate the anatomical aspects of the electric field in relation to effects on speech and movement during DBS in the subthalamic nucleus. Methods: Patient-specific finite element models of DBS were developed for simulation of the electric field in 10 patients. In each patient, speech intelligibility and movement were assessed during 2 electrical settings, i.e. 4 V (high) and 2 V (low). The electric field was simulated for each electrical setting. Results: Movement was improved in all patients for both high and low electrical settings. In general, high-amplitude stimulation was more consistent in improving the motor scores than low-amplitude stimulation. In 6 cases, speech intelligibility was impaired during high-amplitude electrical settings. Stimulation of part of the fasciculus cerebellothalamicus from electrodes positioned medial and/or posterior to the center of the subthalamic nucleus was recognized as a possible cause of the stimulation-induced dysarthria. Conclusion: Special attention to stimulation-induced speech impairments should be taken in cases when active electrodes are positioned medial and/or posterior to the center of the subthalamic nucleus.
Background and Objective: Total tumor resection in patients with glioblastoma multiforme (GBM) is difficult to achieve due to the tumor's infiltrative way of growing and morphological similarity to the surrounding functioning brain tissue. The diagnosis is usually subjectively performed using a surgical microscope. The objective of this study was to develop and evaluate a hand-held optical touch pointer using a fluorescence spectroscopy system to quantitatively distinguish healthy from malignant brain tissue intraoperatively. Study Design/Materials and Methods:A fluorescence spectroscopy system with pulsed modulation was designed considering optimum energy delivery to the tissue, minimal photobleaching of PpIX and omission of the ambient light background in the operating room (OR). 5-aminolevulinic acid (5-ALA) of 5 mg/kg body weight was given to the patients with a presumed glioblastoma multiforme prior to surgery. During the surgery a laser pulse at 405 nm was delivered to the tissue. PpIX in glioblastoma tumor cells assigned with peaks at 635 nm and 704 nm was detected using a fiber optical probe.Results/Conclusion: By using the pulsed fluorescence spectroscopy, PpIX fluorescence is quantitatively detected in the glioblastoma multiforme. An effective suppression of low power lamp background from the recorded spectra in addition to a significant reduction of high power surgical lights is achieved.
Deep brain stimulation (DBS) is an established treatment for Parkinson's disease (PD). Success of DBS is highly dependent on electrode location and electrical parametersettings. The aim of this study was to develop a general method for setting up patient-specific 3D computer models of DBS, based on magnetic resonance images, and to demonstrate the use of such models for assessing the position of the electrode contacts and the distribution of the electric field in relation to individual patient anatomy. A software tool was developed for creating finite element DBS-models. The electric field generated by DBS was simulated in one patient and the result was visualized with isolevels and glyphs. The result was evaluated and corresponded well with reported effects and side effects of stimulation. It was demonstrated that patient-specific finite element models and simulations of DBS can be useful for increasing the understanding of the clinical outcome of DBS.
New deep brain stimulation (DBS) electrode designs offer operation in voltage and current mode and capability to steer the electric field (EF). The aim of the study was to compare the EF distributions of four DBS leads at equivalent amplitudes (3 V and 3.4 mA). Finite element method (FEM) simulations (n = 38) around cylindrical contacts (leads 3389, 6148) or equivalent contact configurations (leads 6180, SureStim1) were performed using homogeneous and patient-specific (heterogeneous) brain tissue models. Steering effects of 6180 and SureStim1 were compared with symmetric stimulation fields. To make relative comparisons between simulations, an EF isolevel of 0.2 V/mm was chosen based on neuron model simulations (n = 832) applied before EF visualization and comparisons. The simulations show that the EF distribution is largely influenced by the heterogeneity of the tissue, and the operating mode. Equivalent contact configurations result in similar EF distributions. In steering configurations, larger EF volumes were achieved in current mode using equivalent amplitudes. The methodology was demonstrated in a patient-specific simulation around the zona incerta and a “virtual” ventral intermediate nucleus target. In conclusion, lead design differences are enhanced when using patient-specific tissue models and current stimulation mode.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.