1998
DOI: 10.1016/s0889-5406(98)70234-3
|View full text |Cite
|
Sign up to set email alerts
|

Clinical comparison and performance perspective of three aligning arch wires

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
63
0
2

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 59 publications
(69 citation statements)
references
References 18 publications
1
63
0
2
Order By: Relevance
“…Unrealistic force variants at which plateau levels are reached in the stressstrain curve of NiTi wires could be another reason. Evans et al 7 found no statistically significant difference in alignment capabilities of medium force active martensitic rectangular NiTi wire, multistranded stainless steel wire, and graded force active martensitic NiTi wire. However, for studying the alignment capabilities of the anterior segment of the arch, investigators had included upper and lower anterior segments together.…”
Section: Discussionmentioning
confidence: 97%
See 2 more Smart Citations
“…Unrealistic force variants at which plateau levels are reached in the stressstrain curve of NiTi wires could be another reason. Evans et al 7 found no statistically significant difference in alignment capabilities of medium force active martensitic rectangular NiTi wire, multistranded stainless steel wire, and graded force active martensitic NiTi wire. However, for studying the alignment capabilities of the anterior segment of the arch, investigators had included upper and lower anterior segments together.…”
Section: Discussionmentioning
confidence: 97%
“…7 The main difference from Little's index 27 is that tooth positions were measured in all three dimensions. Here the attempt is made to measure the amount of tooth movement to Factor* material is the interaction term between 'Factor' and 'material' in the ANOVA.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies compared archwires with each other and some studies compared archwire sequences instead of comparing initial archwires (14)(15)(16)(17)(18)(19)(20)(21)(22). Based on the studies on archwire sequences, when there is a significant difference between two sequences, it is more difficult to determine which wire or wires of that particular sequence was or were more effective and led to a significant difference.…”
Section: History and General Properties Of Different Orthodontic Archmentioning
confidence: 99%
“…As mentioned before, multi-stranded SS wires can also be the choice for the alignment phase. Researches have shown that their use is as successful as that of nickel-titanium at the time of initial alignment (13,18).…”
Section: History and General Properties Of Different Orthodontic Archmentioning
confidence: 99%