2017
DOI: 10.2116/analsci.33.335
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic Separation of Cd from Plants via Anion-Exchange Resin for an Isotope Determination by Multiple Collector ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 38 publications
(61 reference statements)
0
6
0
Order By: Relevance
“…However, batch number must be indicated when SPEX Cd is reported in different laboratories, because of the large difference in δ 114/110 Cd NIST SRM 3108 values obtained in different batches, for example δ 114/110 Cd NIST SRM 3108 of Spex‐1 are −0.09 ± 0.01 ‰ for Lot: 74‐075219K and −1.25 ± 0.06‰ for Lot: CL6‐30CDY relative to NIST SRM 3108 (Wei et al . , ). BAM I012 yielded a δ 114/110 Cd NIST SRM 3108 value of −1.31 ± 0.09‰ (2 s , n = 13) and a δ 112/110 Cd NIST SRM 3108 value of −0.66 ± 0.08‰ (2 s , n = 13), which is indistinguishable from value reported by previous studies (Abouchami et al .…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…However, batch number must be indicated when SPEX Cd is reported in different laboratories, because of the large difference in δ 114/110 Cd NIST SRM 3108 values obtained in different batches, for example δ 114/110 Cd NIST SRM 3108 of Spex‐1 are −0.09 ± 0.01 ‰ for Lot: 74‐075219K and −1.25 ± 0.06‰ for Lot: CL6‐30CDY relative to NIST SRM 3108 (Wei et al . , ). BAM I012 yielded a δ 114/110 Cd NIST SRM 3108 value of −1.31 ± 0.09‰ (2 s , n = 13) and a δ 112/110 Cd NIST SRM 3108 value of −0.66 ± 0.08‰ (2 s , n = 13), which is indistinguishable from value reported by previous studies (Abouchami et al .…”
Section: Resultsmentioning
confidence: 99%
“…Wei et al . (, ) reported that the δ 114/110 Cd NIST SRM 3108 value of Spex‐1 Cd solution (lot no. : 74‐075219K) relative to NIST SRM 3108 was −0.09 ± 0.01‰, and the value of GSB Cd relative to Spex‐1 Cd was −0.56 ± 0.03‰.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…9 In the literature, there are many methods for the determination of metal ions at trace levels. Some of them are flame atomic absorption spectroscopy (FAAS), 10 graphite furnace atomic absorption spectroscopy (GFAAS), 11 inductively coupled plasma mass spectroscopy (ICP-MS), 12 atomic fluorescence spectroscopy (AFS), 13 inductively coupled plasma optic emission spectroscopy (ICP-OES). 14 Among them, FAAS is a robust analytical method that gives accurate and precise measurements, and it is ideal for routine laboratory usage.…”
Section: Introductionmentioning
confidence: 99%