2008
DOI: 10.1007/s12272-001-1271-9
|View full text |Cite
|
Sign up to set email alerts
|

Chiral separation of fluvastatin enantiomers by capillary electrophoresis

Abstract: An analytical CE method was developed for the enantiomeric purity determination of fluvastatin enantiomers. Fluvastatin enantiomers were separated on an uncoated fused silica with 100 mM-borate solution containing 30 mg/mL of (2-hydroxypropyl)-beta-cyclodextrin (HP-beta-CD) as running buffer and fenoprofen as an internal standard. The linearity was observed within a 400-700 microg/mL concentration range (r(2)>or=0.995) for both fluvastatin enantiomers. The repeatability expressed as coefficient of variation (C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2009
2009
2014
2014

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 18 publications
(17 reference statements)
0
9
0
1
Order By: Relevance
“…The CE method was developed for the enantiomeric purity determination of fluvastatin enantiomers [117]. Its principle involves the formation of diastereoisomer complexes after addition of neutral cyclodextrin to the running buffer.…”
Section: Capillary Electrophoresismentioning
confidence: 99%
“…The CE method was developed for the enantiomeric purity determination of fluvastatin enantiomers [117]. Its principle involves the formation of diastereoisomer complexes after addition of neutral cyclodextrin to the running buffer.…”
Section: Capillary Electrophoresismentioning
confidence: 99%
“…The sensitivity of this study was similar when compared with those of in literature findings for the assay of FLU in pharmaceutical preparations. [15][16][17][18][19] No peak was found at the retention time of FLU in placebo solution. The good recoveries of FLU were in the range of 99.25-99.80% in determining of the accuracy of the method (Table 2).…”
Section: Methods Validationmentioning
confidence: 95%
“…7 FLU has been determined by high performance liquid chromatographic methods with UV detection, 8 fluorometric detection [9][10][11][12] and mass spectrometric detection 13,14 in human plasma. A few methods such as spectrophotometric, 15 electrometric 16,17 and electrophoretic 18,19 have been reported for the assay of FLU in pharmaceutical preparations. The antioxidant effects of FLU have also been studied in humans [20][21][22] and animals.…”
Section: Fluvastatin (Flu) (3r5s6e)-rel-7-[3-(4-fluorophenyl)-1-(1mentioning
confidence: 99%
“…2‐HP‐β‐CD seems to be the most widely applicable neutral CD derivative. It was used for the enantiomeric separation of amino acids, in combination with SDS and PEO , and chiral drugs, such as fluvastatin , β 2 ‐agonists , etodolac , the antimycotic drugs, ketoconazole and terconazole , and lodipine . This is due to its excellent solubilizer features and its excellent selectivity because of its polar and nonpolar substituent groups and the extra chiral centers that these groups provide.…”
Section: Chiral Selectorsmentioning
confidence: 99%