2017
DOI: 10.1016/j.ancr.2017.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Chemically modified carbon paste ion-selective electrodes for determination of atorvastatin calcium in pharmaceutical preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0
6

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 26 publications
0
3
0
6
Order By: Relevance
“…ISEs are widely used primarily because of their simplicity, are relatively inexpensive, and significantly reduce analysis time compared to other techniques [ 30 ]. For the determination of the active ingredients of various pharmaceuticals, ISEs are usually prepared by incorporating the electroactive substances into polyvinyl chloride (PVC)-based membranes [ 3 , 24 , 31 , 32 , 33 , 34 , 35 , 36 ] or carbon paste membranes [ 35 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ]. Compared to PVC-based membranes, CPEs are not only faster and easier to fabricate, but also offer easier surface renewal, almost imperceptible ohmic resistance, and certainly more opportunities to modify the membrane composition to improve measurement selectivity [ 48 , 49 ].…”
Section: Introductionmentioning
confidence: 99%
“…ISEs are widely used primarily because of their simplicity, are relatively inexpensive, and significantly reduce analysis time compared to other techniques [ 30 ]. For the determination of the active ingredients of various pharmaceuticals, ISEs are usually prepared by incorporating the electroactive substances into polyvinyl chloride (PVC)-based membranes [ 3 , 24 , 31 , 32 , 33 , 34 , 35 , 36 ] or carbon paste membranes [ 35 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ]. Compared to PVC-based membranes, CPEs are not only faster and easier to fabricate, but also offer easier surface renewal, almost imperceptible ohmic resistance, and certainly more opportunities to modify the membrane composition to improve measurement selectivity [ 48 , 49 ].…”
Section: Introductionmentioning
confidence: 99%
“…In general, and from reported articles, it is evident that both the selected organic compound [ 38 , 39 , 58 , 59 ], usually used as a precipitating agent for IAC, and binder [ 30 , 37 , 39 , 40 ] strongly influence the response of CPE and its characteristics. Various studies and citations can be found in the literature with binder proportions, but all of them in a range between 15 and 55 wt% [ 27 , 30 , 36 , 58 , 60 ].…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, ion-selective electrodes have found applications in clinical, industrial, and environmental analysis [ 31 ]. One of the most common procedures for the development of ISE (for the determination of drugs, whether the active ingredient is a component of pharmaceutical preparations or biological fluids) is the incorporation of a lipophilic ion-pair-associated complex into a polyvinyl chloride (PVC) based membrane [ 31 , 32 , 33 , 34 , 35 ] or the preparation of carbon paste electrodes (CPE) [ 5 , 24 , 30 , 31 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 ].…”
Section: Introductionmentioning
confidence: 99%
“…To je dijelom moguće spriječiti kratkoročnim skladištenjem na hladnom i mračnom mjestu. 2 Najčešće ispitivana veziva u posljednjih desetak godina u razvoju CPE jesu: dibutilftalat (DBP), 4,6,[8][9][10][11][12][13][14][15][16][17][18][19][20] bis(2-etilheksil)ftalat (DOP), 6,9,21,22,[10][11][12][13][14]16,18,20 parafinsko ulje (PO), 4,5,15,[23][24][25][26] tris(2-etilheksil)fosfat (TEPh), [16][17][18] 2-nitrofenil-oktil-eter (NPOE) 4,6,9,12,14,15,27 te bis(2-etilheksil)adipat (DEHA) 10,12,13,15,16 šća p...…”
Section: Uvodunclassified
“…ion-associated complex), ionski aditivi, nanomaterijali i dr. Izbor reagensa za taloženje elektroaktivne tvari, tj. IAC-a 6,8,9,11,12,14,[16][17][18][19]20,45 i maseni udio IAC-a u pasti najviše utječu na odzivne karakteristike CPE. Testiranja utjecaja IAC-a provođena su u rasponu od 0 do 5 %, 4,6,9,[16][17][18] od 0 do 10 %, 11,12,15,20 O vrsti i dodanoj količini soli (ionskih aditiva), kao često upotrebljavanim modifikatorima CPE, također znatno ovisi osjetljivost senzora.…”
Section: Uvodunclassified