2014
DOI: 10.1016/j.sab.2013.11.004
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of toners and inkjets by laser ablation spectrochemical methods and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
47
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 50 publications
(97 citation statements)
references
References 27 publications
1
47
0
Order By: Relevance
“…Few reports have demonstrated the application of LIBS for the analysis of writing inks [5,[18][19][20] and only two for printing ink analysis [21,22]. One of these studies reported the use of LIBS and LA-ICP-MS to study the elemental composition of inks from more than 200 pens [5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Few reports have demonstrated the application of LIBS for the analysis of writing inks [5,[18][19][20] and only two for printing ink analysis [21,22]. One of these studies reported the use of LIBS and LA-ICP-MS to study the elemental composition of inks from more than 200 pens [5].…”
Section: Introductionmentioning
confidence: 99%
“…The application of LA-ICP-MS and LIBS for the analysis of printed documents was recently investigated by Trejos et al [21], who reported the characterisation of toners and inkjet inks by laser-based methods and SEM-EDX using different statistical and comparison methods (i.e., ANOVA with Tukey's post hoc test and PCA). The results indicated that SEM-EDX was not suitable for the examination of 12 black inkjet samples since elemental concentrations were below the detection limits for the majority of elements except sulphur, providing only 47.4% discrimination between possible comparison pairs.…”
Section: Introductionmentioning
confidence: 99%
“…Table 4 summarizes the optimized parameters for the analysis of offset printing inks. and all the n Ar n Ar isotopic combinations from m/z n + n 72 to 80) were not selected for detection, during the scanning method to prevent detector saturation 11,41 .…”
Section: 4 Optimization Of Parameters For Offset Printing Inksmentioning
confidence: 99%
“…The resolution of the 39 K peak was customized to 0.4amu (atomic mass units) to minimize interferences from Ca and Ar isotopes. For the rest of the elements and their isotopes the default quadrupole resolution of 0.7amu was used 11,41 . The intensity of the elements reflected the concentration of the element in the ink sample.…”
Section: 4 Optimization Of Parameters For Offset Printing Inksmentioning
confidence: 99%
See 1 more Smart Citation