2008
DOI: 10.1002/rcm.3655
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of the molecular mass distribution of pullulans by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry using 2,5‐dihydroxybenzoic acid butylamine (DHBB) as liquid matrix

Abstract: The performances of several matrices were investigated for the accurate determination of the molecular mass distributions of pullulans by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The ionic liquid matrix (ILM) 2,5-dihydroxybenzoic acid butylamine (DHBB) gave better and more reliable results than the crystalline matrices 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP). With the ILM it was possible to obtain spectra of pullulans up to more… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 38 publications
(52 reference statements)
0
16
0
Order By: Relevance
“…Due to their ability to dissolve a wide range of analytes they have been used in a number of analytical techniques (Schnöll-Bitai, et al, 2008). In 2001, ionic liquids were introduced as matrices in MALDI MS for the analysis of biomolecules and synthetic polymers (Tholey & Heinzle, 2006).…”
Section: Ionic Liquid-assisted Electrospray Ionization Of Polysaccharmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to their ability to dissolve a wide range of analytes they have been used in a number of analytical techniques (Schnöll-Bitai, et al, 2008). In 2001, ionic liquids were introduced as matrices in MALDI MS for the analysis of biomolecules and synthetic polymers (Tholey & Heinzle, 2006).…”
Section: Ionic Liquid-assisted Electrospray Ionization Of Polysaccharmentioning
confidence: 99%
“…the determination of the molecular mass distribution of polysaccharides (pullulans) which are used as calibration standards in aqueous size-exclusion chromatography (Schnöll-Bitai et al, 2008). In most cases the ionization process in ILMs led to protonated species of the analytes, very similar to solid matrices.…”
Section: Tandem Mass Spectrometry Of Tagged and Permethylated Polysacmentioning
confidence: 99%
“…This indicates that with high laser power less selectivity in ionization, and, consequently, less discrimination of higher homologs with HABA, occurs. Likewise, for the molecular mass distribution of synthetic polymers best results were achieved at high laser power since here less discrimination of high mass compounds occurs, unfortunately with the risk of in‐source fragmentation of lower homologs of the polymer . No fragmentation was detected in our experiments.…”
Section: Resultsmentioning
confidence: 67%
“…Likewise, for the molecular mass distribution of synthetic polymers best results were achieved at high laser power since here less discrimination of high mass compounds occurs, unfortunately with the risk of in-source fragmentation of lower homologs of the polymer. [35,36] No fragmentation was detected in our experiments.…”
Section: Maldi-tof Mass Spectrometrymentioning
confidence: 92%
See 1 more Smart Citation