Characterization of Summer Savory (Satureja hortensis L.) Honey by Physico-Chemical Parameters and Chromatographic / Spectroscopic Techniques (GC-FID/MS, HPLC-DAD, UV/VIS and FTIR-ATR)

Abstract: Abstract. Satureja hortensis L. unifloral honey was characterized by pollen analysis, electrical conductivity, pH and extensively by chromatographic and spectroscopic techniques. UV / VIS spectroscopy measurements revealed total phenol content of 682.1 mg GAE / kg by Folin-Ciocalteu assay, antioxidant capacity by DPPH assay of 1.7 mmol TEAC / kg and by FRAP assay of 4.3 mmol Fe 2+ / kg as well as CIE L*a*b*C ab *h°a b chromaticity coordinates. GC-MS after headspace solid-phase microextraction (HS-SPME) reveale… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(19 citation statements)
references
References 14 publications
0
19
0
Order By: Relevance
“…To our knowledge, no reports exist about the colorimetric analysis of pollen, and only a few papers dealt about the colorimetric evaluation of honey [ 59 , 60 ]. Moreover, literature data only reported colorimetric parameters for solved samples analysed by spectrophotometry, and did not show any reflectance curves.…”
Section: Resultsmentioning
confidence: 99%
“…To our knowledge, no reports exist about the colorimetric analysis of pollen, and only a few papers dealt about the colorimetric evaluation of honey [ 59 , 60 ]. Moreover, literature data only reported colorimetric parameters for solved samples analysed by spectrophotometry, and did not show any reflectance curves.…”
Section: Resultsmentioning
confidence: 99%
“…In this figure, several distinct absorption peaks can be seen in the3405.88, 2427. 61 [15,25] and N-H group of amide A [15,26]. The peak at 2427.61 cm À1 was related to the C-H group of Alkanes [15,25,26].…”
Section: Fourier Transform Infrared (Ft-ir) Spectroscopymentioning
confidence: 98%
“…The purpose of the FT-IR experiment is the recognition of the possible functional groups of bio-molecules that are involved in capping, effective stabilization, and reduction of recently synthesized AgNPs [15,25]. FT-IR analysis of AgNPs was shown in Table 1 and Figure 4.…”
Section: Fourier Transform Infrared (Ft-ir) Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…Gas chromatography-mass spectrometry (GC-MS) analysis. This analysis was performed according to a previously reported method 33 using an Agilent Technologies GC equipped with a mass selective detector, HP-5MS. A 5% phenyl methyl siloxane capillary column with dimensions of 30.0 m × 250 µm × 0.25 µm was used, and helium was used as the carrier gas at 1 ml/min.…”
Section: Effect Of Nacl Concentration Ph and Temperature On The Growthmentioning
confidence: 99%