2014 IEEE PES Transmission &Amp; Distribution Conference and Exposition - Latin America (PES T&D-La) 2014
DOI: 10.1109/tdc-la.2014.6955259
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of contacts degradation in circuit breakers through the dynamic contact resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…The dynamic contact resistance is measured during the breaking tests. In paper [4,5], a dynamic contact resistance measuring device based on Arduino software and hardware platform was developed. The device is used to measure the dynamic contact resistance of the low-voltage circuit breaker, and it is more effective to evaluate the state of the arc extinguishing chamber of the circuit breaker.…”
Section: Introductionmentioning
confidence: 99%
“…The dynamic contact resistance is measured during the breaking tests. In paper [4,5], a dynamic contact resistance measuring device based on Arduino software and hardware platform was developed. The device is used to measure the dynamic contact resistance of the low-voltage circuit breaker, and it is more effective to evaluate the state of the arc extinguishing chamber of the circuit breaker.…”
Section: Introductionmentioning
confidence: 99%
“…Nonetheless, in [13] it is reported that the method presented by [12] can damage some breaker mechanism when restoring it back into service since it requires the substitution of the standard operating mechanism by an auxiliary mechanical device. However, in [14] it is presented that the DRM can be used at the nominal speed since the injection system has a value of 300 A as applied DC current. In addition, [14] reinforces the use of the area under the DRM curve as a valid evaluating parameter for contact degradation.…”
Section: Introductionmentioning
confidence: 99%
“…However, in [14] it is presented that the DRM can be used at the nominal speed since the injection system has a value of 300 A as applied DC current. In addition, [14] reinforces the use of the area under the DRM curve as a valid evaluating parameter for contact degradation.…”
Section: Introductionmentioning
confidence: 99%
“…The arcing contacts get eroded and become shorter after each opening operation due to arc energy. Severely eroded arcing contacts may directly reflect the considerable decrease in the breaking capacity of CBs [13]. Therefore, the erosion of arcing contacts is a critical parameter for the condition assessment of contact sets.…”
Section: Introductionmentioning
confidence: 99%
“…Dynamic contact RM (DRM) is proved to be an effective method to diagnose the extinguishing chamber [13, 6–12]. Four‐line method and high DC amperages are usually applied in DRM to assure high accuracy of the test results [911].…”
Section: Introductionmentioning
confidence: 99%