2016
DOI: 10.1016/j.aca.2016.10.016
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of conformers and dimers of antithrombin by capillary electrophoresis-quadrupole-time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
28
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 33 publications
1
28
0
Order By: Relevance
“…They were able to separate two conformers and concluded that a sheathless interface is best suited to maintain conformational integrity after ionization . Another study demonstrated the identification of several conformers of antithrombin based on their different charge‐state‐distributions . Belov et al.…”
Section: Analytical Applicationsmentioning
confidence: 99%
“…They were able to separate two conformers and concluded that a sheathless interface is best suited to maintain conformational integrity after ionization . Another study demonstrated the identification of several conformers of antithrombin based on their different charge‐state‐distributions . Belov et al.…”
Section: Analytical Applicationsmentioning
confidence: 99%
“…CE allows protein analysis under near-physiological conditions, allowing detection of the different conformers. 149 151 For example, the unfolding of wild-type β2-microglobulin under nondenaturing conditions was investigated with CE-UV 149 and CE-ESI-MS. 150 In the latter study, several interfaces and mass spectrometers were compared. With CE-ESI-TOF MS proteoforms differing by 1 Da only could be assigned and sheathless interfacing appeared best suited to preserve protein structure integrity.…”
Section: Applicationsmentioning
confidence: 99%
“…A CE-MS method developed to separate the conformers and dimers of the drug antithrombin employed a neutral poly(vinyl alcohol)-coated capillary. 151 The protein conformation was preserved by using a BGE at physiological pH. The developed method allowed the detection of the native, latent, and heterodimer conformers in formulation.…”
Section: Applicationsmentioning
confidence: 99%
“…In the case of Aclotine, the MS data between the separated conformers showed dissimilarities concerning the relative abundance of each detected charge state, suggesting that some protonation sites were accessible to the solvent depending on the conformation of the protein (Figure ). That original work is particularly interesting because it illustrates the powerful analytical methodologies achievable at the moment solely using CE/MS …”
Section: Applications and Potential Of Ce/ms For The Analysis Of Biommentioning
confidence: 99%
“…(B) and (C) mass spectra of peaks 1 and 2, respectively. Adapted from Marie et al Copyright (2016) Elsevier BV…”
Section: Applications and Potential Of Ce/ms For The Analysis Of Biommentioning
confidence: 99%