2002
DOI: 10.1021/ac020304z
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of a Focal Plane Camera Fitted to a Mattauch−Herzog Geometry Mass Spectrograph. 1. Use with a Glow-Discharge Source

Abstract: A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in the single to hundreds of nanograms per gram regime; isotope ratio accuracy and precision better than 5% error and 0.2%… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
53
0

Year Published

2003
2003
2022
2022

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 54 publications
(53 citation statements)
references
References 25 publications
(39 reference statements)
0
53
0
Order By: Relevance
“…This instrument has been coupled to several ionization sources, including both dc and pulsed glow discharges (GD) [21,28], a microwave plasma torch (MPT) [29], and an ICP [27]. Since the ICP-MHMS has been described previously, only the operating parameters pertinent to the present experiment will be detailed.…”
Section: Inductively Coupled Plasma Mass Spectrometermentioning
confidence: 99%
See 3 more Smart Citations
“…This instrument has been coupled to several ionization sources, including both dc and pulsed glow discharges (GD) [21,28], a microwave plasma torch (MPT) [29], and an ICP [27]. Since the ICP-MHMS has been described previously, only the operating parameters pertinent to the present experiment will be detailed.…”
Section: Inductively Coupled Plasma Mass Spectrometermentioning
confidence: 99%
“…The accumulated ion signal on each collector is integrated with its own capacitive trans-impedance amplifier; the array of amplifiers is read with a low-noise multiplexer. Further details on the FPC and its coupling to the MHMS can be found elsewhere [21]. The operating conditions of the LA-ICP-MHMS-FPC instrument are summarized in Table 1.…”
Section: Focal Plane Cameramentioning
confidence: 99%
See 2 more Smart Citations
“…Alternatively, a double-focusing mass spectrograph can be fitted with a focal-plane camera, thereby creating the MS-equivalent of CCD cameras. These devices can monitor the entire mass range of interest continuously and simultaneously (4). TOFMS has also been explored as a method for overcoming some of the limitations of PSMS and is gaining popularity for multielemental and multiisotopic analysis of fast transient signals (5)(6)(7)(8).…”
mentioning
confidence: 99%