2000
DOI: 10.1016/s0021-9673(00)00411-8
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis and off-line capillary electrophoresis–electrospray ionization quadrupole time-of-flight tandem mass spectrometry of carbohydrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
27
0

Year Published

2001
2001
2010
2010

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 32 publications
(28 citation statements)
references
References 11 publications
1
27
0
Order By: Relevance
“…In lower abundance, the Ser-linked Neu5Ac 2 Hex 2 HexNAc 2 was detected as a doubly charged ion at m/z 707.75. Although previously [53] the off-line CE/MS was reported to require rather high amounts of glycopeptide sample for detection, the final concentration of the fraction was here approximately 3 pmol/mL. In the case of ammonium formate, the 75 nL/min flow rate exhibited by the NanoMate chip system yielded a fair S/N by only 30 scans of signal accumulation (Fig.…”
Section: Complex Biological Mixtures Of Glycopeptidesmentioning
confidence: 81%
See 2 more Smart Citations
“…In lower abundance, the Ser-linked Neu5Ac 2 Hex 2 HexNAc 2 was detected as a doubly charged ion at m/z 707.75. Although previously [53] the off-line CE/MS was reported to require rather high amounts of glycopeptide sample for detection, the final concentration of the fraction was here approximately 3 pmol/mL. In the case of ammonium formate, the 75 nL/min flow rate exhibited by the NanoMate chip system yielded a fair S/N by only 30 scans of signal accumulation (Fig.…”
Section: Complex Biological Mixtures Of Glycopeptidesmentioning
confidence: 81%
“…In the case of ammonium formate, the 75 nL/min flow rate exhibited by the NanoMate chip system yielded a fair S/N by only 30 scans of signal accumulation (Fig. 11) under the sample consumption of approximately 0.4 pmol, which is a superior sensitivity in comparison with the capillary-based experiments [53,54]. Due to the high spray stability, the MS/MS investigation of a low abundant doubly charged ion at m/z 707.75 attributed to Neu5Ac 2 Hex 2 HexNAc 2 -Ser was greatly enhanced (Fig.…”
Section: Complex Biological Mixtures Of Glycopeptidesmentioning
confidence: 96%
See 1 more Smart Citation
“…The use of powerful mass spectrometers can partially counterbalance this drawback, as demonstrated by Zamfir and co-workers [27,36,64], who successfully characterized a number of glycoconjugates by CE off-line coupled with MS.…”
Section: Analysis Of Glycans From Glycoproteinsmentioning
confidence: 99%
“…To date, the main articles regarding the CE-MS of saccharidic compounds found in literature include the analysis of (i) standard mixtures [42,[47][48][49][50][51][52]; (ii) carbohydrates in nutrition [19,[53][54][55][56][57][58][59]; (iii) glycans from glycoproteins [60][61][62][63][64][65]; (iv) carbohydrates in drug development [45,[66][67][68][69][70][71][72][73][74][75][76][77][78][79][80][81].…”
Section: Introductionmentioning
confidence: 99%