Calibration of GafChromic XR‐RV3 radiochromic film for skin dose measurement using standardized x‐ray spectra and a commercial flatbed scanner

Abstract: XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
66
2
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 75 publications
(76 citation statements)
references
References 44 publications
(62 reference statements)
7
66
2
1
Order By: Relevance
“…Comparison between table 1 and 2 shows halogens (Cl and Br) in the polyester layer of XR-RV3 but igure 3 showed that dose pro iles from both ilms are nearly identical at megavoltage energies. McCabe et al (6) showed that the white side of XR-RV3 absorbed more radiation compared to the orange side. The phantom ( igure 1) was designed to cause differential iltering of the soft beam components but this did not cause a deviation in the dose pro iles in igure 3.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Comparison between table 1 and 2 shows halogens (Cl and Br) in the polyester layer of XR-RV3 but igure 3 showed that dose pro iles from both ilms are nearly identical at megavoltage energies. McCabe et al (6) showed that the white side of XR-RV3 absorbed more radiation compared to the orange side. The phantom ( igure 1) was designed to cause differential iltering of the soft beam components but this did not cause a deviation in the dose pro iles in igure 3.…”
Section: Discussionmentioning
confidence: 99%
“…EBT is semi-transparent while XR-RV3 ilm has a yellow polyester coating that faces the radiation source during dose measurement (6) . An EPSON Perfection V330 Photo scanner (Scan software version 3.9.0.0US) was used to scan the ilm (7) .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Investigation of orientation test of XR-RV3 film was done by McCabe et al 2011. They shown that the film response to kV X-ray was much influenced by the orientation of film.…”
Section: B Orientation Test Of Filmmentioning
confidence: 99%
“…The sensitivity of gafchromic film XR-RV3 with size of 35.56 cm x 43.18 cm is in the range of 0.01Gy to 30 Gy within energy range of 30 keV to 30 MeV. This film is dedicated for measuring entrace dose during interventional fluoroscopy (Blair et al 2009;McCabe et al 2011).…”
Section: Introductionmentioning
confidence: 98%