A theoretical investigation of factors limiting the detective quantum efficiency (DQE) of active matrix flat-panel imagers (AMFPIs), and of methods to overcome these limitations, is reported. At the higher exposure levels associated with radiography, the present generation of AMFPIs is capable of exhibiting DQE performance equivalent, or superior, to that of existing film-screen and computed radiography systems. However, at exposure levels commonly encountered in fluoroscopy, AMFPIs exhibit significantly reduced DQE and this problem is accentuated at higher spatial frequencies. The problem applies both to AMFPIs that rely on indirect detection as well as direct detection of the incident radiation. This reduced performance derives from the relatively large magnitude of the square of the total additive noise compared to the system gain for existing AMFPIs. In order to circumvent these restrictions, a variety of strategies to decrease additive noise and enhance system gain are proposed. Additive noise could be reduced through improved preamplifier, pixel and array design, including the incorporation of compensation lines to sample external line noise. System gain could be enhanced through the use of continuous photodiodes, pixel amplifiers, or higher gain x-ray converters such as lead iodide. The feasibility of these and other strategies is discussed and potential improvements to DQE performance are quantified through a theoretical investigation of a variety of hypothetical 200 microm pitch designs. At low exposures, such improvements could greatly increase the magnitude of the low spatial frequency component of the DQE, rendering it practically independent of exposure while simultaneously reducing the falloff in DQE at higher spatial frequencies. Furthermore, such noise reduction and gain enhancement could lead to the development of AMFPIs with high DQE performance which are capable of providing both high resolution radiographic images, at approximately 100 microm pixel resolution, as well as variable resolution fluoroscopic images at 30 fps.
The risks and benefits of using computed tomography (CT) as opposed to another imaging modality to accomplish a particular clinical goal should be weighed carefully. To accurately assess radiation risks and keep radiation doses as low as reasonably achievable, radiologists must be knowledgeable about the doses delivered during various types of CT studies performed at their institutions. The authors of this article propose a process improvement approach that includes the estimation of effective radiation dose levels, formulation of dose reduction goals, modification of acquisition protocols, assessment of effects on image quality, and implementation of changes necessary to ensure quality. A first step toward developing informed radiation dose reduction goals is to become familiar with the radiation dose values and radiation-associated health risks reported in the literature. Next, to determine the baseline dose values for a CT study at a particular institution, dose data can be collected from the CT scanners, interpreted, tabulated, and graphed. CT protocols can be modified to reduce overall effective dose by using techniques such as automated exposure control and iterative reconstruction, as well as by decreasing the number of scanning phases, increasing the section thickness, and adjusting the peak voltage (kVp setting), tube current-time product (milliampere-seconds), and pitch. Last, PDSA (plan, do, study, act) cycles can be established to detect and minimize negative effects of dose reduction methods on image quality.
Amorphous silicon/cesium iodide (a-Si:H/CsI:Tl) flat-panel (FP)-based full-field digital mammography systems have recently become commercially available for clinical use. Some investigations on physical properties and imaging characteristics of these types of detectors have been conducted and reported. In this perception study, a phantom containing simulated microcalcifications (microCs) of various sizes was imaged with four detector systems: a FP system, a small field-of-view charge coupled device (CCD) system, a high resolution computed radiography (CR) system, and a conventional mammography screen/film (SF) system. The images were reviewed by mammographers as well as nonradiologist participants. Scores reflecting confidence ratings were given and recorded for each detection task. The results were used to determine the average confidence-rating scores for the four imaging systems. Receiver operating characteristics (ROC) analysis was also performed to evaluate and compare the overall detection accuracy for the four detector systems. For calcifications of 125-140 microm in size, the FP system was found to have the best performance with the highest confidence-rating scores and the greatest detection accuracy (Az = 0.9) in the ROC analysis. The SF system was ranked second while the CCD system outperformed the CR system. The p values obtained by applying a Student t-test to the results of the ROC analysis indicate that the differences between any two systems are statistically significant (p<0.005). Differences in microC detectability for the large (150-160 microm) and small (112-125 microm) size microC groups showed a wider range of p values (not all p values are smaller than 0.005, ranging from 0.6 to <0.001) compared to the p values obtained for the medium (125-140 microm) size microC group. Using the p values to assess the statistical significance, the use of the average confidence-rating scores was not as significant as the use of the ROC analysis p value for p value.
A detailed theoretical and empirical investigation of additive noise for indirect detection, active matrix flat-panel imagers (AMFPIs) has been performed. Such imagers comprise a pixelated array, incorporating photodiodes and thin-film transistors (TFTs), and an associated electronic acquisition system. A theoretical model of additive noise, defined as the noise of an imaging system in the absence of radiation, has been developed. This model is based upon an equivalent-noise-circuit representation of an AMFPI. The model contains a number of uncorrelated noise components which have been designated as pixel noise, data line thermal noise, externally coupled noise, preamplifier noise and digitization noise. Pixel noise is further divided into the following components: TFT thermal noise, shot and 1/f noise associated with the TFT and photodiode leakage currents, and TFT transient noise. Measurements of various additive noise components were carried out on a prototype imaging system based on a 508 microm pitch, 26 x 26 cm2 array. Other measurements were performed in the absence of the array, involving discrete components connected to the preamplifier input. Overall, model predictions of total additive noise as well as of pixel, preamplifier, and data line thermal noise components were in agreement with results of their measured counterparts. For the imaging system examined, the model predicts that pixel noise is dominated by shot and 1/f noise components of the photodiode and TFT at frame times above approximately 1 s. As frame time decreases, pixel noise is increasingly dominated by TFT thermal noise. Under these conditions, the reasonable degree of agreement observed between measurements and model predictions provides strong evidence that the role of TFT thermal noise has been properly incorporated into the model. Finally, the role of the resistance and capacitance of array data lines in the model was investigated using discrete component circuits at the preamplifier input. Measurements of preamplifier noise and data line thermal noise components as a function of input capacitance and resistance were found to be in reasonable agreement with model predictions.
Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-contrast performance of an amorphous silicon/cesium iodide (aSi/Csl)-based flat-panel digital chest radiography system is compared to those of a screen/film and a computed radiography system by measuring their contrast-detail curves. Also studied were the effects of image enhancement in printing the digital images and dependence on kVp and incident exposure. It was found that the FP system demonstrated significantly better low-contrast performance than the SF or CR systems. It was estimated that a dose savings of 70%-90% could be achieved to match the low-contrast performance of the FP images to that of the SF images. This dose saving was also found to increase with the object size. No significant difference was observed in low-contrast performances between the SF and CR systems. The use of clinical enhancement protocols for printing digital images was found to be essential and result in better low-contrast performance. No significant effects were observed for different kVps. From the results of this contrast-detail phantom study, the aSi/CsI-based flat-panel digital chest system should perform better under clinical situations for detection of low-contrast objects such as lung nodules. However, proper processing prior to printing would be essential to realizing this better performance.
The purpose of this study was to evaluate the use of digital x-ray imaging detectors for the measurement of diagnostic x-ray tube focal spot size using a slit camera. Slit camera images of two focal spots for a radiographic x-ray tube were acquired with direct-exposure film (DF) (as specified by the National Electrical Manufacturers Association [NEMA] Standards Publication No. XR 5, 1992), computed radiography (CR) imaging plates, and an a-Si:H/CsI:Tl-based flat-panel (FP) detector. Images obtained with the CR and the FP were acquired over a broad range of detector entrance exposure levels. The DF slit images were evaluated according to NEMA specifications (visually, using a 7x magnifying glass with reticule) by six medical physicists. Additionally, the DF images were digitized and the focal spot sizes obtained from the digital profiles of the slit. The CR and the FP images were analyzed in a manner similar to the digitized DF images. It took less than 20 minutes for a complete CR or FP measurement of focal spot size in two dimensions. In comparison, a typical DF measurement with visual evaluation takes at least 60 minutes, in our experience. In addition to a great reduction in measurement time achieved by using digital detectors, the tube loading requirements were reduced to approximately 20 mAs compared with approximately 1000 mAs when using the DF technique. The calculated focal spot sizes for CR and FP differed from those of digitized DF by -2.4% to +4.8% (sigma=2.5%), far less than the -16.6% to +9.3% (sigma=8.1%) variability introduced by the visual evaluation of the slit image. In addition, the calculated focal spot sizes for the CR and the FP images maintained a coefficient of variation <1.0% over the broad range of exposure levels. Based upon these results, we conclude that (1) FP and CR detectors yield consistent results in measurements of x-ray tube focal spot sizes, (2) compared to DF, CR and FP significantly reduce measurement time and tube loading requirements, (3) CR and FP readily permit digital profile analysis, thereby eliminating observer error, and (4) unlike DF, CR and FP are independent of exposure level.
The development of the highest resolution, large-area, active-matrix, flat-panel imager (AMFPI) thus far reported is described. This imager is based on a 97 jtm pixel pitch array with each pixel comprising a single a-Si:H TFT coupled to a discrete a-Si:H n-i-p photodiode. While the initial configuration chosen for fabrication is a 2048x2048 pixel array, a larger monolithic array format of 3072x4096 pixels is also permitted by the design. When coupled to an overlying scintillator such as a phosphor screen or CsI:Tl, the array allows indirect detection of incident radiation. The array is operated in conjunction with a recently completed electronic acquisition system featuring asynchronous operation, a large addressing range, fast analog signal extraction and digitization, and 16-bit digitization. This imager, whose empirical characterization will be reported in a subsequent paper, was developed as an engineering prototype to allow investigation of the performance limits of the most aggressive array designs permitted by present active-matrix technology. The development of this new imager builds upon knowledge acquired from the iterative design, fabrication, and quantitative evaluation of earlier engineering prototypes based on a series of 127 im pitch arrays. This paper summarizes the general program of research leading to this new device and puts this in the context of world-wide developments in indirect and direct detection AMFPI technology. Some limitations of present AMFPI technology are described, and possible solutions are discussed.Specifically, the incorporation of multiplexers based on poly-crystalline silicon circuitry into the array design, to facilitate very high resolution imagers, are proposed. In addition, strategies to significantly improve AMFPI performance at very low exposures, such as those commonly encountered in fluoroscopy, involving the reduction of additive noise (such as through lower preamplifier noise) and the enhancement of system gain (such as through the use of lead iodide) are discussed and initial calculations illustrating potential levels ofperformance are presented.
The purpose of this study was to characterize image quality and dose performance with GE CT iterative reconstruction techniques, adaptive statistical iterative reconstruction (ASiR), and model-based iterative reconstruction (MBIR), over a range of typical to low-dose intervals using the Catphan 600 and the anthropomorphic Kyoto Kagaku abdomen phantoms. The scope of the project was to quantitatively describe the advantages and limitations of these approaches. The Catphan 600 phantom, supplemented with a fat-equivalent oval ring, was scanned using a GE Discovery HD750 scanner at 120 kVp, 0.8 s rotation time, and pitch factors of 0.516, 0.984, and 1.375. The mA was selected for each pitch factor to achieve CTDI vol values of 24, 18, 12, 6, 3, 2, and 1 mGy. Images were reconstructed at 2.5 mm thickness with filtered back-projection (FBP); 20%, 40%, and 70% ASiR; and MBIR. The potential for dose reduction and low-contrast detectability were evaluated from noise and contrast-to-noise ratio (CNR) measurements in the CTP 404 module of the Catphan. Hounsfield units (HUs) of several materials were evaluated from the cylinder inserts in the CTP 404 module, and the modulation transfer function (MTF) was calculated from the air insert. The results were confirmed in the anthropomorphic Kyoto Kagaku abdomen phantom at 6, 3, 2, and 1 mGy. MBIR reduced noise levels five-fold and increased CNR by a factor of five compared to FBP below 6 mGy CTDI vol , resulting in a substantial improvement in image quality. Compared to ASiR and FBP, HU in images reconstructed with MBIR were consistently lower, and this discrepancy was reversed by higher pitch factors in some materials. MBIR improved the conspicuity of the high-contrast spatial resolution bar pattern, and MTF quantification confirmed the superior spatial resolution performance of MBIR versus FBP and ASiR at higher dose levels. While ASiR and FBP were relatively insensitive to changes in dose and pitch, the spatial resolution for MBIR improved with increasing dose and pitch. Unlike FBP, MBIR and ASiR may have the potential for patient imaging at around 1 mGy CTDI vol . The improved low-contrast detectability observed with MBIR, especially at low-dose levels, indicate the potential for considerable dose reduction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.