2012
DOI: 10.1016/j.ajo.2011.11.017
|View full text |Cite
|
Sign up to set email alerts
|

Calcification in Hydrophilic Intraocular Lenses Associated With Injection of Intraocular Gas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
100
0
5

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 73 publications
(107 citation statements)
references
References 18 publications
2
100
0
5
Order By: Relevance
“…Similarly to the pattern seen in the Oft Cryl® IOL, calcification within the pupillary and anterior capsulorrhexis margins has been described in eyes in which gas or air 1) was injected intracamerally to treat Descemet's membrane detachment, to aid in graft adherence in endothelial transplants; 2) was injected to treat hypotony following trabeculoplasty; or 3) went into the anterior chamber after injection in the vitreous cavity to treat retinal detachment and ocular hypotony (2)(3)(4)(5)(6)(7)(8) . In these lenses, calcium granules were also found on the surface and subsurface of the IOLs.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Similarly to the pattern seen in the Oft Cryl® IOL, calcification within the pupillary and anterior capsulorrhexis margins has been described in eyes in which gas or air 1) was injected intracamerally to treat Descemet's membrane detachment, to aid in graft adherence in endothelial transplants; 2) was injected to treat hypotony following trabeculoplasty; or 3) went into the anterior chamber after injection in the vitreous cavity to treat retinal detachment and ocular hypotony (2)(3)(4)(5)(6)(7)(8) . In these lenses, calcium granules were also found on the surface and subsurface of the IOLs.…”
Section: Discussionmentioning
confidence: 99%
“…Previous papers have described cases of IOL opacification in hydrophilic acrylic IOLs from different manufacturers (2)(3)(4)(5)(6)(7)(8)(9)(10)(11) . However, to the best of our knowledge, this is the first peer-reviewed report on Oft Cryl® IOL opacification.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…GİL opasifikasyonu, GİL değişimi-ni de gerektirebilen ciddi görme azalmalarına neden olabilir. Tüm GİL materyallerinde opasifikasyon gelişebilmektedir ve bunun GİL üretimi veya polimer yapısındaki bir sorundan kaynaklandığı düşünülmektedir (6). Bu olgu sunumunda GİL opasifikasyonu ile karışan geç postoperatif KBS tanısı alan olgunun ayırıcı tanısı ve tedavi yönetimi tartışılmıştır.…”
Section: Introductionunclassified
“…This series supports previous observations that such opacification appears to be almost unique to hydrophilic acrylic IOL's, and furthermore, having air or gas in the anterior chamber appears to be a risk factor. 2,3 However, it is certainly possible for this complication to occur without rebubbling. Although all four cases had rebubbling in this series, 1 in our recently published UK series only two of the five cases had rebubbling.…”
mentioning