2020
DOI: 10.1016/j.engstruct.2019.109977
|View full text |Cite
|
Sign up to set email alerts
|

Building damages during the September 19, 2017 earthquake in Mexico City and seismic retrofitting of existing first soft-story buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(10 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…Another recent intense earthquakes in Mexico , with high magnitude (8.2 Mw) caused significant damages in housing which especially affected the soft-story buildings that are subject to strong motions (JARA et al, 2020). It caused damage of 600 buildings and more than 1000 buildings classified in different risk levels.…”
Section: Geologic Setting Of Mexicomentioning
confidence: 99%
“…Another recent intense earthquakes in Mexico , with high magnitude (8.2 Mw) caused significant damages in housing which especially affected the soft-story buildings that are subject to strong motions (JARA et al, 2020). It caused damage of 600 buildings and more than 1000 buildings classified in different risk levels.…”
Section: Geologic Setting Of Mexicomentioning
confidence: 99%
“…A transfer story has several types, for example, transfer beam (girder) [1], transfer slab (plate) [2][3][4][5][6][7], or transfer box [8], among which the transfer slab structure is quite popular due to being free from the limitation of the forms of the upper and lower structures and the flexible axes distribution of upper and lower stories. Due to the space requirement of subway station, the height of frame structure differs greatly from the first floor to the second floor, resulting in structural stiffness mutation and the formation of soft-story [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. Buildings with soft-story had a significantly higher proportion of serious damage than other conventional types of buildings after the earthquake in Hyogo-ken Nambu (1995) as well as in Mexico City (1985) [7].…”
Section: Introductionmentioning
confidence: 99%
“…Buildings with soft-story had a significantly higher proportion of serious damage than other conventional types of buildings after the earthquake in Hyogo-ken Nambu (1995) as well as in Mexico City (1985) [7]. The internal force of the vertical anti-lateral component of the structure is transferred downward by the horizontal conversion component, and the structure displays obvious vertical irregularity [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27]. The plate-column joints of this structure have complex forces under seismic loads; therefore, some scholars have carried out studies on such structures from the perspective of the joints [4][5][6][28][29][30][31][32][33][34][35][36].…”
Section: Introductionmentioning
confidence: 99%
“…In the recent years all over the world an elevated number of seismic events was seen, especially in the southern subregion of Europe [1]- [4]. These events caused important damages to the architectural heritage and lead to the need of in-depth investigation on the quality of materials and buildings.…”
Section: Introductionmentioning
confidence: 99%