Abstract:Taking the frame-supported shear wall structure of a 102.1 m high metro depot as the test object, the structure has obvious vertical irregularity, and a quasi-static test was carried out on the structural model with the scale of 1/5. The damage development and strain of the structure were observed by applying displacement loads under different seismic actions, and the experimental phenomena and measured data were analyzed. The results show that the safety performance of the structure meets the seismic requirem… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.