2010
DOI: 10.1016/j.apenergy.2010.04.021
|View full text |Cite
|
Sign up to set email alerts
|

Boil off gas (BOG) management in Spanish liquid natural gas (LNG) terminals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0
7

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(39 citation statements)
references
References 12 publications
0
32
0
7
Order By: Relevance
“…This normal boiling point characteristic makes the N 2 vaporise with great ease, placing itself at the upper part of the tank in a gaseous state. Therefore, N 2 concentration in boil-off (the NG vapour generated through the heat input in the tank) is greater than in the LNG that is sent to the regasification process [50]. For these reasons, the mixture of light LNG is selected to proceed with the study of the proposed plant.…”
Section: Composition Of Lngmentioning
confidence: 99%
“…This normal boiling point characteristic makes the N 2 vaporise with great ease, placing itself at the upper part of the tank in a gaseous state. Therefore, N 2 concentration in boil-off (the NG vapour generated through the heat input in the tank) is greater than in the LNG that is sent to the regasification process [50]. For these reasons, the mixture of light LNG is selected to proceed with the study of the proposed plant.…”
Section: Composition Of Lngmentioning
confidence: 99%
“…In large-scale terminals, BOG is either recondensed using a portion of the cold LNG sendout, used as a fuel source to power prime movers, or reliquefied using refrigerators [2][3][4][5][6]. No BOG venting is permitted during normal operation.…”
Section: Introductionmentioning
confidence: 99%
“…Since it is difficult to measure the BOG components by experimental methods [11], calculations for BOG properties have been done by Aspen HYSYS based on the LNG storage tank operation condition and LNG compositions [16,18]. The mole fraction of components for BOG is obtained by mass balance, heat balance and phase equilibrium ( Table 2).…”
Section: Lng Properties Calculationmentioning
confidence: 99%
“…Although the direct compression process is simple in device, it has been proven that the energy-utilization efficiency of BOG recondensation system is 30% -60% higher than that of compressing BOG directly to a distribution pipeline [10]. Meanwhile, the re-condensation process is proven to require 50% lower power consumption and less maintenance [11].…”
Section: Introductionmentioning
confidence: 99%