Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Fractionation will be reduced significantly if molecular ions like Li 2 BO 1 are used, because the relative mass difference for 6 Li 2 BO 1 versus 7 Li 2 BO 1 is almost one order of magnitude smaller compared to the atomic ions 6 Li 1 versus 7 Li 1 . [17][18][19]57 In contrast, the magnitude of mass fractionation in isotope ratio analysis of the heaviest elements, such as 235 U/ 238 U or 240 Pu/ 239 Pu, is of the order of half a per cent or less per one mass unit difference. 58,59 The mass fractionation needs to be corrected in order to reduce the introduced bias (see Chapter 6 and Section 14.3.2).…”
Section: Mass Fractionation and Temperature Profilementioning
confidence: 99%
“…Fractionation will be reduced significantly if molecular ions like Li 2 BO 1 are used, because the relative mass difference for 6 Li 2 BO 1 versus 7 Li 2 BO 1 is almost one order of magnitude smaller compared to the atomic ions 6 Li 1 versus 7 Li 1 . [17][18][19]57 In contrast, the magnitude of mass fractionation in isotope ratio analysis of the heaviest elements, such as 235 U/ 238 U or 240 Pu/ 239 Pu, is of the order of half a per cent or less per one mass unit difference. 58,59 The mass fractionation needs to be corrected in order to reduce the introduced bias (see Chapter 6 and Section 14.3.2).…”
Section: Mass Fractionation and Temperature Profilementioning
confidence: 99%
“…A procedure for the determination of Li isotopic composition in sea-water involved reduction of the Na content by passing the sample through a column of hydrated Sb 2 O 5 which is an ion exchanger specific for removal of Na. 267 No further separation was carried out as any ion exchange procedure would induce isotopic fractionation. The samples (40 ng Li as LiOH) were loaded directly onto single rhenium filaments using a silica gel procedure.…”
Section: Sample Preparationmentioning
confidence: 99%
“…11 Kim et al investigated the complex formation of azacrown indoaniline with Li(I) ions on a UV-Vis spectrophotometer. 12 Other available techniques include thermal ionization mass spectrometry (TIMS), 13 inductively coupled plasma atomic emission spectrometry (ICP-AES), 14 differential pulse anodic stripping voltammetry (DPASV), 15 capillary electrophoresis (CE), 16 ow injection analysis (FIA) 17 and ion chromatography (IC). 18 Fluorescent sensing is known to proffer distinct advantages over most other instruments.…”
Section: Introductionmentioning
confidence: 99%