Bilateral Interference of Wind Loads Induced on Duplicate Building Models of Various Shapes

Abstract: The current investigation focuses on the results of an experimental investigation of Square-plan-shape and Remodel-triangle-shape building model's varied interference conditions between duplicate building models of 1:300 scale (at 100% blockage) on wind-induced pressure and base moments at fixed 10% of the height of the instrumented model. Under current working conditions, the study concludes that -1 > Interference Factor > 1 as experienced by the Remodel-triangle-shape model results in reduced performance of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…It is observed that in the fourth case where the incidence angle is 90 degrees the range of Cp values become positive in all the three models.  The reason for the changes in Cp value is because of the formation of vortex i.e., the swirling of wind particles about a particular axis because of which the Cp value decreases for the face A [10,11].…”
Section: Validationsmentioning
confidence: 99%
“…It is observed that in the fourth case where the incidence angle is 90 degrees the range of Cp values become positive in all the three models.  The reason for the changes in Cp value is because of the formation of vortex i.e., the swirling of wind particles about a particular axis because of which the Cp value decreases for the face A [10,11].…”
Section: Validationsmentioning
confidence: 99%
“…Through few published studies on interference effects in unusually shaped buildings, it was found that this parameter has significant influence on interference effects. To quantify this influence, local pressure distribution was investigated by Pal et al (2021aPal et al ( , 2021b, finding maximum suctions in a triangular model 40% higher than in square models and moments in the cross-wind direction dominating the overall model behavior due to its unsymmetrical crosssectional shape.…”
Section: Introductionmentioning
confidence: 99%
“…The case study revealed that numerical simulations can be reliable for more complex wind simulations and corner modified building model show better performance to reduce drag force. [20] experimentally investigated experimentally the wind effects on fish plan shaped building model and discussed the pressure distribution pattern using pressure contours.…”
Section: Introductionmentioning
confidence: 99%