2014
DOI: 10.14295/ras.v28i2.27399
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação Da Qualidade Da Água Subterrânea No Entorno De Um Aterro Sanitário

Abstract: The aim of this work was to evaluate the groundwater quality in the surrounding area of Visconde do Rio Branco landfill in Minas Gerais State. Between September 2010 to October 2011 the parameters pH, temperature, dissolved oxygen, electrical conductivity, E. coli, total coliforms, Al, Cd, Cu, Pb, Cr, Fe, Mn, Hg, and Zn were monitored in the leachate and in the wells, and besides those mentioned, biological oxygen demand and chemical oxygen demand were monitored in the streams present in the area of study. Hig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
1
0
4

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 1 publication
(2 reference statements)
0
1
0
4
Order By: Relevance
“…This contamination can spread not only by surface water, but also can reach the water table, a possible source of water for the local population. Oliveira and Pasqual (2004), Lopes et al (2007) and Nakamura et al (2014), verified the contamination of the water table by heavy metals in their stidies. Arsenic, Cadmium, Lead, Copper, Mercury and Zinc are systematically referred to as sources of urban waste deposited in landfills or dumps, domestic sewage, mining, industrial dumping and agricultural activities (Campos et al, 2009;Coelho, 2012;Cotta et al, 2006;Egreja Filho et al, 1999;Jesus et al, 2004;Lima and Santos, 2012;Macêdo, 2007;Marins et al, 2004;Nakamura et al, 2014;Nriagu e Pacyna, 1988;Ribeiro et al, 2012;Santana and Barroncas, 2007;Silva et al, 2016;WHO, 2004;2007;2010a;2010b;2010c;Yu et al, 2014).…”
Section: Resultsmentioning
confidence: 74%
“…This contamination can spread not only by surface water, but also can reach the water table, a possible source of water for the local population. Oliveira and Pasqual (2004), Lopes et al (2007) and Nakamura et al (2014), verified the contamination of the water table by heavy metals in their stidies. Arsenic, Cadmium, Lead, Copper, Mercury and Zinc are systematically referred to as sources of urban waste deposited in landfills or dumps, domestic sewage, mining, industrial dumping and agricultural activities (Campos et al, 2009;Coelho, 2012;Cotta et al, 2006;Egreja Filho et al, 1999;Jesus et al, 2004;Lima and Santos, 2012;Macêdo, 2007;Marins et al, 2004;Nakamura et al, 2014;Nriagu e Pacyna, 1988;Ribeiro et al, 2012;Santana and Barroncas, 2007;Silva et al, 2016;WHO, 2004;2007;2010a;2010b;2010c;Yu et al, 2014).…”
Section: Resultsmentioning
confidence: 74%
“…Resultados similares foram obtidos por Araújo et al (2011) onde foi verificada a presença de parasitas patogênicos e coliformes em amostras de água coletadas nos pontos de abastecimento coletivo e nos recipientes de armazenamento de água de moradias na Comunidade Rural Sepé Tiarajú-SP, considerando a água utilizada como um fator de risco à saúde. Nakamura et al (2014), ao avaliar a qualidade da água subterrânea no entorno do aterro sanitário do município de Visconde do Rio Branco, Minas Geraisque pertence à bacia hidrográfica do rio Paraíba do Sul e ao qual são enviadas diariamente aproximadamente 25 toneladas de resíduos de origem domésticaevidenciaram contaminação microbiológica por coliformes totais e Escherichia coli, mais evidentes em períodos chuvosos, possivelmente causada por problemas de infraestrutura na construção do aterro tais como na drenagem do lixiviado, no sistema de impermeabilização das lagoas e do aterro bem como na cobertura dos sistemas que constituem as células de disposição de resíduos.…”
Section: Discussionunclassified
“…O ponto de coleta PA1 teve o maior índice de condutividade elétrica, com 8,2 dS m -1 , Tabela 3. Segundo Nakamura et al (2014) a elevação da condutividade elétrica pode estar relacionada a dissolução de íons naturais, e provenientes da percolação de lixiviado oriundos de áreas contaminadas.…”
Section: Análise Da Qualidade Da áGua No Lixão Desativadounclassified