2010
DOI: 10.1155/2010/545030
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Determination of Fiber-Length Distribution in Composite Material Using 3D CT Data

Abstract: Determining fiber length distribution in fiber reinforced polymer components is a crucial step in quality assurance, since fiber length has a strong influence on overall strength, stiffness, and stability of the material. The approximate fiber length distribution is usually determined early in the development process, as conventional methods require a destruction of the sample component. In this paper, a novel, automatic, and nondestructive approach for the determination of fiber length distribution in fiber r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(24 citation statements)
references
References 8 publications
0
24
0
Order By: Relevance
“…The fibres may thus be partially hollow and partially solid, hindering the use of above methods. Algorithms introduced in [22][23][24] are based on analysis of the local orientation of fibres in order to separate them from each other, and thus seem to be better suited for fibres of irregular shape.…”
Section: Introductionmentioning
confidence: 99%
“…The fibres may thus be partially hollow and partially solid, hindering the use of above methods. Algorithms introduced in [22][23][24] are based on analysis of the local orientation of fibres in order to separate them from each other, and thus seem to be better suited for fibres of irregular shape.…”
Section: Introductionmentioning
confidence: 99%
“…(Fu et al, 2002, Clarke et al, 1995 Recently, three dimensional methods based on X-ray tomography (CT) have also been developed. (Shen et al, 2004;Kastner et al, 2008b;Teßmann et al, 2010) Depending on the tomographic method used, the results can only be estimates or detailed analyses. Since data quality is determined by resolution as well as the appearance of artefacts, at the moment the best CT-data quality can be achieved by Synchrotron scanning (SCT).…”
Section: Introductionmentioning
confidence: 99%
“…Alternative evaluation criteria could be e.g. the smallest gray-value, the variance of gray-values or a function introduced in Teßmann et al (2010) which takes advantage of the relation of cylindrical structures to the eigenvalues of its Hessian matrices and emphasize those voxel which exhibit the greatest likelihood of belonging to the center lines of fibers.…”
Section: Reconstruction Of Fibersmentioning
confidence: 99%
“…For example, the length and curvature of single fibers influence their mechanical strength, stiffness, and electrical resistance (Teßmann et al, 2010), where the arrangement and the form of fibers can be changed by the production process or as a result of degradation phenomena. To better understand the coherence of the microstructure of the considered material and the physical processes therein, the development of stochastic models describing the geometry of GDL is of great importance.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation