2012
DOI: 10.1111/j.1939-1676.2012.00928.x
|View full text |Cite
|
Sign up to set email alerts
|

Atrial‐Based Pacing for Sinus Node Dysfunction in Dogs: Initial Results

Abstract: Based on this small group of dogs, clinically important AV block does not appear to occur in the long-term for dogs with SND. Risks of lead perforation, complete dislodgment, and rising thresholds for pacing, possibly because of microdislodgment, may be related to the initial skill level of the operator or the leads that were used. Use of leads with reduced torque at the lead tip, higher flexibility, increased lead-tip surface of contact with the endocardium or, more likely, use of alternate locations for paci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…These findings support the routine use of dual-paced, dual-sensed, dual mode of response rate modulation, rather than AAIR, pacing in patients with SSS [67]. Also, in human medicine, in patients with sinus standstill, dualchamber pacing is considered the pacing mode of choice [67], whereas AAIR is not considered for routine use [130]. Unnecessary right ventricular pacing should be systematically avoided in patients with sinus standstill by programming the PM with a long AV interval [135,136].…”
Section: Indications For Pacing and Choice Of Pacing Modementioning
confidence: 54%
“…These findings support the routine use of dual-paced, dual-sensed, dual mode of response rate modulation, rather than AAIR, pacing in patients with SSS [67]. Also, in human medicine, in patients with sinus standstill, dualchamber pacing is considered the pacing mode of choice [67], whereas AAIR is not considered for routine use [130]. Unnecessary right ventricular pacing should be systematically avoided in patients with sinus standstill by programming the PM with a long AV interval [135,136].…”
Section: Indications For Pacing and Choice Of Pacing Modementioning
confidence: 54%
“…SSS has been described in various dog breeds, such as pugs, dachshunds, cocker spaniels and West Highland white terriers, but femaleminiature schnauzers seem to be the most affected [7,11]; syncope is a clinical sign commonly present in patients with sinus node dysfunction [12,18,20]. Episodes of syncope were reported by the owner of the female schnauzer referred to in the present report, and throughout the patient's care, syncope was present.…”
Section: Discussionmentioning
confidence: 46%
“…A subcutaneous pocket was created at the ventral aspect of the thoracic incision to accommodate a generator, which was connected to the pacemaker lead. The pacemaker was made by Boston Scientific and was an Advantio model (K082) 7 [basic frequency 60-60 (BOL-ERI-ppm], magnetic frequency 100-85 (BOL-ERI-ppm), connector size IS-1 (mm), polarity UNI/BI, leads, and titanium battery). After the surgical procedure, the patient remained under observation for 24 h. At the time of writing, the clinical signs have ceased.…”
Section: Casementioning
confidence: 99%
See 1 more Smart Citation
“…This review also suggests that an active fixation lead implanted into the RA appendage (44 implants in this review) by experienced operators using appropriate techniques is safe in the short term and effective (in terms of lead electrical performance). Such an approach has not been fully utilized clinically, due to the perception that an optimal lead design for veterinary patients does not yet exist, that the thin walled RA appendage will not necessarily allow for proper fixation into the tissue, the presumption that there is a greater risk of perforation, and recognition of the need to develop optimized techniques to make atrial pacing more reliable [ 5 , 24 ].…”
Section: Discussionmentioning
confidence: 99%